HP Insight Management WBEM Provider Events Reference Guide

Windows crash dump file has not been enabled. Probable Cause: The system has not
been configured to save debugging information in the event of a system crash.
Recommended Action: Configure writing debugging information using Windows
Control Panel>System>Advance>Startup and Recovery. WBEM EventID: 5248. WBEM
ProviderName: FPL_IndicationProvider.Warning12088
Windows paging file size or the free space of the memory dump target volume is
too small. Probable Cause: The paging file or the free space of the memory dump
target volume is not large enough to store the crash dump information in the event
of a system crash. Recommended Action: Check the crash dump settings for the
recommended Paging File size using the HP System Management Home Page or use
Startup and Recovery under Windows System Properties. Also execute the disk
cleanup to free some space on the target volume of the memory dump file. WBEM
EventID: 5249. WBEM ProviderName: FPL_IndicationProvider.Warning12090
PCI interlock open with PCI power applied. Probable Cause: PCI interlock has been
opened with PCI slot power on. Recommended Action: power down slot attempting
to remove PCI card. WBEM EventID: 5230. WBEM ProviderName:
FPL_IndicationProvider.Warning12091
Fault detected on low drop out regulator on I/O backplane. Probable Cause: A
defective component could cause this fault. Recommended Action: Check the
backplane. WBEM EventID: 5237. WBEM ProviderName: FPL_IndicationProvider.Error12101
Fault detected on low drop out regulator on main backplane. Probable Cause: The
specified low dropout regulator on the main backplane is reporting a fault.
Recommended Action: Check the main backplane. WBEM EventID: 5238. WBEM
ProviderName: FPL_IndicationProvider.Error12102
Fault detected hot swap controller of specified core IO. Probable Cause: The hot swap
controller for the specified core IO is reporting fault. Recommended Action: Check
the specified core IO. WBEM EventID: 5250. WBEM ProviderName:
FPL_IndicationProvider.Error12103
An error occurred while retrieving the crossbar chip number. Probable Cause: System
firmware had difficulty determining the crossbar number from the graph data
structure. Recommended Action: Capture IPMI event logs, look for additional errors.
Contact your HP Support Representative to analyze the fabric. WBEM EventID: 5251.
WBEM ProviderName: FPL_IndicationProvider.Warning12109
One or more of the cells are not configured for Cell-Local Memory (CLM) mode.
Probable Cause: The initial partition configuration may have not specified 100%
Cell-Local Memory or may have been reconfigured incorrectly. Recommended Action:
Reconfigure the partition or reset the CLM setting on one or more cells in your
partition using the Partition Manager or ParCLI tools. WBEM EventID: 5259. WBEM
ProviderName: FPL_IndicationProvider.Warning12119
Double DRAM chip sparing events have been invoked. Probable Cause: System
firmware has detected and corrected memory errors. Double DRAM chip sparing
events have been invoked to help mitigate this condition. On the next reboot, system
firmware will test the specified memory components, and may take them offline if
the errors persist. Recommended Action: Contact your HP support representative
to check the specified memory. WBEM EventID: 5260. WBEM ProviderName:
FPL_IndicationProvider.Warning12120
A platform error was detected by the firmware/hardware, and corrected by using a
spare channel. Probable Cause: Hardware has detected many link retries on one of
its channels and has switched to a spare one. Recommended Action: Monitor the
situation and contact your HP support representative to check the affected hardware.
WBEM EventID: 5261. WBEM ProviderName: FPL_IndicationProvider.Warning12121
System Firmware detected an internal deadlock in the firmware tree. Probable Cause:
Internal System Firmware bug. Recommended Action: Notify HP support. WBEM
EventID: 8295. WBEM ProviderName: FPL_IndicationProvider.Error12123
80 WBEM Provider Event Tables