HP Insight Management WBEM Provider Events Reference Guide

A platform error was detected by the firmware/hardware, and corrected by using a
spare channel. Probable Cause: The error occurred between the crossbar chips on
the backplane(s). Recommended Action: Contact your support representative to have
the backplane and / or connections between backplanes checked. WBEM EventID:
5263. WBEM ProviderName: FPL_IndicationProvider.Warning12127
A platform error was detected by the firmware/hardware, and corrected by using a
spare channel. Probable Cause: The error occurred between the cell controller and
the IO controller. Recommended Action: Contact your support representative to have
the Cell Controller to IO Interface checked. Check these FRUs: Cell-IO cable, IO
chassis, IO backplane, cell, or system backplane. WBEM EventID: 5264. WBEM
ProviderName: FPL_IndicationProvider.Warning12128
Multiple platform errors were detected and corrected by the firmware/hardware.
Probable Cause: The errors occurred between the cell controller and the backplane.
Recommended Action: Contact your support representative to have the Cell Controller
to backplane Interface checked. WBEM EventID: 5265. WBEM ProviderName:
FPL_IndicationProvider.Warning12129
Multiple platform errors were detected and corrected by the firmware/hardware.
Probable Cause: The errors occurred between the crossbar chips on the backplane(s).
Recommended Action: Contact your support representative to have the backplane
and / or connections between backplanes checked. WBEM EventID: 5266. WBEM
ProviderName: FPL_IndicationProvider.Warning12130
Multiple platform errors were detected and corrected by the firmware/hardware.
Probable Cause: The errors occurred between the cell controller and the IO controller.
Recommended Action: Contact your support representative to have the Cell Controller
to IO Interface checked. Check these FRUs: Cell-IO cable, IO chassis, IO backplane,
cell, or system backplane. WBEM EventID: 5267. WBEM ProviderName:
FPL_IndicationProvider.Warning12131
The server ID does not match the cabinet type. Probable Cause: The cabinet type is
not in agreement with the server identification information. The server identification
information is viewable using the ID command from the MP's command menu. The
cabinet type is displayed in the top line of the cabinet status shown when the PS
command from the MP's command menu is used to target a compute cabinet.
Recommended Action: Contact your support representative to have the server
identification information and cabinet type checked. WBEM EventID: 5269. WBEM
ProviderName: FPL_IndicationProvider.Error12132
Duplicate DIMM serial numbers have been detected. Data field gives physical location
of DIMM. Check for other events specifying other DIMMs with same serial number.
Probable Cause: Multiple DIMMs have the same serial number. Recommended
Action: Replace DIMMs with duplicate serial numbers. Ensure new DIMMs have
unique serial numbers. WBEM EventID: 6564. WBEM ProviderName:
FPL_IndicationProvider.Warning12135
The MP has lost lan communication with the UPS. Probable Cause: The UPS has been
disconnected or has failed. Recommended Action: Insure the UPS is connected
properly and use the UPS command to verify that it can communicate with the MP.
If not, try replacing the UPS. WBEM EventID: 6833. WBEM ProviderName:
FPL_IndicationProvider.Warning12143
The MP has re-gained lan communication with the UPS. Probable Cause: The UPS
has been connected and can communicate with the MP. Recommended Action: Use
the UPS command to set/verify the desired settings. WBEM EventID: 6834. WBEM
ProviderName: FPL_IndicationProvider.Warning12144
An unrecoverable processor interrupt occurred while in IPF firmware. The data value
is the processor IFA. Probable Cause: Probable bug in System Firmware, EFI driver,
EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset
applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM
Volume 2. Recommended Action: Provide console log containing register dump to
HP Customer Engineer. WBEM EventID: 6569. WBEM ProviderName:
FPL_IndicationProvider.Error12149
Platform Events 81