HP Insight Management WBEM Provider Events Reference Guide

The windows watchdog timer has expired. The partition associated with the cell with
the expired timer will be reset. Probable Cause: Windows had configured the
Windows watchdog timer to either reset or power off the nPartition on a timeout
and the Windows watchdog timer has expired without being refreshed. The nPartition
will either be reset or powered off. Recommended Action: Investigate the operating
system, drivers, Windows applications and event logs for possible causes. If hardware
is suspected, contact HP customer support. WBEM EventID: 6867. WBEM
ProviderName: FPL_IndicationProvider.Error12244
An entity's MP Bus communications controller is reporting a hardware revision that
is known to cause MP Bus communications failures. Probable Cause: An entity's MP
Bus communications controller is reporting a hardware revision that is known to
cause MP Bus communications failures. Recommended Action: Contact your HP
Service Representative to investigate the failing hardware. WBEM EventID: 6875.
WBEM ProviderName: FPL_IndicationProvider.Error12251
12v power to a PCI slot located on the IO Chassis has power faulted. Probable Cause:
Main power at the PCI slot located on the IO Chassis has faulted. Recommended
Action: contact HP support. WBEM EventID: 6877. WBEM ProviderName:
FPL_IndicationProvider.Error12255
SFW detected a failure while optimizing the fabric. Probable Cause: Failure detected
by SFW while the optimizing fabric. Recommended Action: Collect IPMI events and
contact your HP Support Representative for assistance. WBEM EventID: 6888. WBEM
ProviderName: FPL_IndicationProvider.Warning12289
A critical failure occurred during a cell online add or delete. Probable Cause: A critical
failure occurred during a cell online add or delete. Recommended Action: This event
should not happen. Please contact HP. WBEM EventID: 6906. WBEM ProviderName:
FPL_IndicationProvider.Error12291
The cell being added has incompatible hardware or firmware revision with the
partition. Probable Cause: The cell being added has incompatible hardware or
firmware revision with the partition. Recommended Action: Previous events will
give a description of the error that led to this event. These need to be corrected before
the cell can be added. WBEM EventID: 6892. WBEM ProviderName:
FPL_IndicationProvider.Warning12296
The System Firmware revision on the cell being added does not match the partition
firmware revision. Probable Cause: The System Firmware revision on the cell being
added does not match the partition firmware revision. Recommended Action: Update
the System Firmware revision on the cell to be added. WBEM EventID: 6893. WBEM
ProviderName: FPL_IndicationProvider.Warning12297
OpenVMS has detected an unrecoverable event and will reboot. Probable Cause:
This event has been generated because OpenVMS has detected an unrecoverable
failure - software inconsitency or hardware-generated MCA. Recommended Action:
OpenVMS will reboot upon this failure. WBEM EventID: 7242. WBEM ProviderName:
FPL_IndicationProvider.Error12319
Bad cell board (on cellular system), or bad processor board (on non-cellular system).
Probable Cause: Bad cell board (on cellular system), or bad processor board (on
non-cellular system). Recommended Action: Contact your HP support representative
to check the cell board (on cellular systems), or the processor board (on non-cellular
systems) which the specified processor module is located in. WBEM EventID: 6895.
WBEM ProviderName: FPL_IndicationProvider.Warning12324
CPU performance degraded due to excessive errors in third level cache. Probable
Cause: The processor has experienced an excessive number of persistent correctable
errors in its third level cache and as a result performance has degraded. Normally
the processor can dynamically deal with this type of error with no impact on
performance. However, if too many such errors occur then they begin to impact
performance. The processor is still able to operate correctly but its performance is
degraded so it should be replaced. Recommended Action: Contact HP Service for
assistance. WBEM EventID: 6896. WBEM ProviderName: FPL_IndicationProvider.Warning12343
Platform Events 85