HP Insight Management WBEM Provider Events Reference Guide

The IO backplane in the specified cabinet is reporting a non-redundant PCI power
condition. It is possible that one of the PCI bricks is not present or not functioning
properly. Check for PCI brick fault events. Probable Cause: One of the PCI bricks is
not present or not functioning properly. Recommended Action: Check for PCI brick
fault events. WBEM EventID: 7014. WBEM ProviderName: FPL_IndicationProvider.Warning12411
The Root Port initialization detected a PCI express link training failure. Probable
Cause: The RP component detected a PCIe link training error, probably due to failed
hardware. Recommended Action: Reseat or replace the PCIe card; update system
firmware; replace the I/O riser if applicable; replace the motherboard. WBEM EventID:
9886. WBEM ProviderName: FPL_IndicationProvider.Error12489
The Root Port component had insufficient GMMIO to support the PCIe request.
Probable Cause: The RP component had insufficient GMMIO resources to support
a board request. Recommended Action: Replace the faulty card, or remove one or
more PCIe cards to reduce GMMIO requirements. WBEM EventID: 9889. WBEM
ProviderName: FPL_IndicationProvider.Warning12492
HP unsupported DIMM(s) has been detected on this partition. Probable Cause: HP
PFM service has detected one or more HP unsupported DIMMs on this partition.
Recommended Action: Make sure to have HP supported DIMMs installed. WBEM
EventID: 7243. WBEM ProviderName: FPL_IndicationProvider.Warning12557
OS run-time critical shutdown occurred. Probable Cause: The OS has caused the
system to shut down. Recommended Action: Look at OS logs and crash data to
determine why the system shut down. WBEM EventID: 7244. WBEM ProviderName:
FPL_IndicationProvider.Error12560
The amount of power expected to be drawn by the currently operating hardware is
greater than the rating of the currently operating Bulk Power Supplies (BPS). Probable
Cause: A bulk power supply has failed or was removed when the system had the
minimal number of required bulk power supplies. Recommended Action: Replace
the failed or removed bulk power supply. WBEM EventID: 7288. WBEM
ProviderName: FPL_IndicationProvider.Error12586
Bulk power supply (BPS) redundancy has been lost on one or more row(s) of power
supplies in the complex. The further loss of a single BPS or an AC grid will most
likely result in the shutdown of partitions. Probable Cause: A change has occurred
in the number of properly operating bulk power supplies installed in the system.
Recommended Action: Replace missing or failed bulk power supplies. WBEM
EventID: 7292. WBEM ProviderName: FPL_IndicationProvider.Error12589
AC redundancy has been lost on one or more power supplies in the complex. The
further loss of a single Bulk Power Supply (BPS) or the other AC grid will most likely
result in the shutdown of partitions. Probable Cause: A configuration change has
been made to the system that changes the amount of power used. Recommended
Action: Relook at the configuration changes. WBEM EventID: 7294. WBEM
ProviderName: FPL_IndicationProvider.Error12591
The fans that cool a region of the system are not redundant. If an additional fan fails
or is removed from this cooling domain, the partitions on this system will be shut
down to prevent damage. Probable Cause: One or more fans in the cooling domain
have been removed or are not functioning properly. Recommended Action: Removed
failed fan (if any) and insert working fan. WBEM EventID: 7295. WBEM
ProviderName: FPL_IndicationProvider.Error12593
An insufficient number of fans are working in a cooling domain to permit system
operation. Running partitions will be shut down immediately to prevent damage
due to excessive heat. Probable Cause: More than one fan in a cooling domain have
been removed or are not functioning properly. Recommended Action: Remove failed
fan(s), if any, and insert working fans. WBEM EventID: 7297. WBEM ProviderName:
FPL_IndicationProvider.Error12595
Operating system is not using all available processors for the current system. Probable
Cause: Operating system license doesn't allow all processors to be used, or some
processors are disabled / deconfigured. Recommended Action: Verify the correct
operating system license to be used; Verify if all processors are enabled. WBEM
EventID: 7573. WBEM ProviderName: FPL_IndicationProvider.Warning12627
Platform Events 87