HP Insight Management WBEM Provider Events Reference Guide

A Fabric Message Processor (FMP) has unexpectedly reset. The system has recovered
from the problem. Probable Cause: There is a firmware problem. Recommended
Action: Verify that the most recent firmware is installed on the system. WBEM
EventID: 7622. WBEM ProviderName: FPL_IndicationProvider.Error12863
SMI training has failed. Probable Cause: SMI (Scalable Memory Interconnect) link
training has failed. Recommended Action: If seating is not an issue, replace the EMB
(Extended Memory Buffer), followed by the CPU. If not resolved, call support. WBEM
EventID: 8039. WBEM ProviderName: FPL_IndicationProvider.Error13086
DIMM at field location has been previously deallocated and remains deallocated.
Probable Cause: A DIMM has been deallocated due to failure during memory init
sequence. The most probable cause is a faulty DIMM. Other possible causes could
be due to SMI failure, DDR3 training failure, or bad SMB (Scalable Memory Buffer)
initialization. Recommended Action: The first action will be to replace the DIMM. If
that does not solve the issue, replace CPU. If problem still continues to exist, replace
the system board. WBEM EventID: 8040. WBEM ProviderName:
FPL_IndicationProvider.Error13093
Multi-blade conjoined rendezvous has failed. Probable Cause: Event occurs when
rendezous among all known logical processors does not occur. All processors need
to checkin with the monarch processor. Recommended Action: Check if the SBL
(Scalable Blade Link) connector is damaged. Replace if damaged. If not, check, then
replace processor. If problem persists, contact Support. WBEM EventID: 8044. WBEM
ProviderName: FPL_IndicationProvider.Warning13106
Expected blades failed to rendezvous at memory checkpoint. Probable Cause:
Processors failed to rendezvous at memory checkpoint. Recommended Action: Reboot.
If problem persists, replace SBL (Scalable Blade Link), if applicable. If this does not
resolve, then replace processor, then contact Support. WBEM EventID: 8046. WBEM
ProviderName: FPL_IndicationProvider.Warning13117
Expected blades failed to rendezvous at memory test checkpoint. Probable Cause:
Expected processors failed to rendezvous at memory test checkpoint. Recommended
Action: Reseat the SBL and Reboot. If problem still exists, then replace the processor
belonging to the missing thread (see event description for data mask). If problem
persists, then contact Support. WBEM EventID: 8047. WBEM ProviderName:
FPL_IndicationProvider.Warning13118
System topology (CPUs and IOHs) discovered is not a supported topology. Probable
Cause: A QPI hardware error may have occurred. Recommended Action: Try
rebooting the server. If problem persists contact support. WBEM EventID: 8066.
WBEM ProviderName: FPL_IndicationProvider.Error13150
Could not find default QPI data. Probable Cause: A hardware error may have
occurred. Recommended Action: Try rebooting the server. If problem persists contact
support. WBEM EventID: 8067. WBEM ProviderName: FPL_IndicationProvider.Error13152
Detected a CPU QPI link's operation is degraded. Probable Cause: QPI link hardware
has been detected operating with degraded performance. Recommended Action:
Reboot. If problem persists contact support. WBEM EventID: 8068. WBEM
ProviderName: FPL_IndicationProvider.Warning13157
Nested Interrupt occurred. Probable Cause: Firmware issue. Recommended Action:
Contact your HP support representative. WBEM EventID: 8079. WBEM
ProviderName: FPL_IndicationProvider.Error13209
The CPUs across the system or SBL domain must all be the same type. Probable
Cause: The part number of CPUs in the system/SBL domain are not the same.
Recommended Action: The CPUs in the system or SBL domain must be the same
part number. Check the FRU data using the DF command at the CM> menu. The
S/SPEC should match and the core stepping should have a delta no greater than 1
across all CPUs. WBEM EventID: 8080. WBEM ProviderName:
FPL_IndicationProvider.Error13211
The Mezzanine IO Cards must be the same in all blades. Probable Cause: The
Mezzanine IO Cards in all blades of the Domain are different. Recommended Action:
The Mezzanine IO Cards must be the same in all blades of the Domain. WBEM
EventID: 8084. WBEM ProviderName: FPL_IndicationProvider.Warning13214
88 WBEM Provider Event Tables