HP Insight Management WBEM Provider Events Reference Guide

The iLO peer to peer LAN communication between DMP and AMP was not
established. Probable Cause: The iLO peer to peer LAN communication between
Domain MP (DMP) and an Auxiliary MP (AMP) could not be established.
Recommended Action: The management system will attempt to repair itself. If the
management system does not recover refer to the Service Guide to determine how
to reset iLO without a user interface. WBEM EventID: 9865. WBEM ProviderName:
FPL_IndicationProvider.Error13417
Virtual Connect failed to write data into a FRU storage device. Probable Cause: An
error occurred in the interface between system firmware and manageability firmware
while updating FRU data. Recommended Action: Reboot the server and verify that
the system board or mezz card containing this FRU is functioning properly. If not,
replace the failing hardware.Check system logs to see if other NVM errors are related
to this same board / card. If so, replace the board / card containing this FRU.Verify
system and manageability firmware are at their currently supported revisions.If
problems persist, contact Support. WBEM EventID: 9799. WBEM ProviderName:
FPL_IndicationProvider.Warning13497
Virtual Connect failed to save a backup of non-volatile EFI variables into NVM.
Probable Cause: An error occurred in the interface between system firmware and
manageability firmware while saving persistent data. iLO may have been temporarily
busy and may have missed an update. Recommended Action: Verify system and
manageability firmware are at their currently supported revisions. If problems persist,
contact Support. WBEM EventID: 9801. WBEM ProviderName:
FPL_IndicationProvider.Warning13574
Virtual Connect failed to save non-volatile EFI variables into NVM. Probable Cause:
An error occurred in the interface between system firmware and manageability
firmware while saving persistent data. iLO may have been temporarily busy and
may have missed an update. Recommended Action: Verify system and manageability
firmware are at their currently supported revisions. If problems persist, contact
Support. WBEM EventID: 9802. WBEM ProviderName: FPL_IndicationProvider.Warning13575
Virtual Connect failed to erase the EFI variables backup from NVM. Probable Cause:
An error occurred in the interface between system firmware and manageability
firmware while saving persistent data. iLO may have been temporarily busy and
may have missed an update. Recommended Action: Verify system and manageability
firmware are at their currently supported revisions. If problems persist, contact
Support. WBEM EventID: 9803. WBEM ProviderName: FPL_IndicationProvider.Warning13576
IOH persistent error condition detected. Probable Cause: A persistent error on an
I/O bridge or endpoint that cannot be cleared. Recommended Action: Replace the
failed component as indicated by the physical location data field. WBEM EventID:
8261. WBEM ProviderName: FPL_IndicationProvider.Error13606
Generic FRU has header checksum error. Probable Cause: 1. FRU not properly
programmed 2. Manageabilty FW may not be working correctly. Recommended
Action: Review the event log for related MFW events to determine if there is a FRU
read problem.Try a MFW reset via web or text interface. If this fails, verify all the
firmware versions are at a supported revision level and do a full power cycle of the
system. If this still fails, it is likely the FRU requires replacement. WBEM EventID:
8262. WBEM ProviderName: FPL_IndicationProvider.Error13621
MFW is posting a Data Object Table which is one revision below what SFW expects.
Probable Cause: Manageability FW is not at the current supported revision for this
SFW. Recommended Action: Update Manageability FW. WBEM EventID: 8263.
WBEM ProviderName: FPL_IndicationProvider.Warning13622
System Firmware will not work correctly with the shared memory table loaded.
Probable Cause: The System Firmware has detected that Manageability FW has
loaded an incompatible shared memory table. Recommended Action: Ensure the
system FW versions are at a supported revision level.Reset MFW via text or Web
Interface . WBEM EventID: 8264. WBEM ProviderName: FPL_IndicationProvider.Error13624
CPU Late Test failed due to PAL Test Info call failed. Probable Cause: A SFW or CPU
error may have occurred. Recommended Action: If the problem persists replace the
processor. WBEM EventID: 8321. WBEM ProviderName: FPL_IndicationProvider.Warning13692
Platform Events 91