HP Insight Management WBEM Provider Events Reference Guide

System Hive size exceeds warning threshold. Probable Cause: This system has
exceeded the Warning threshold for the System Hive size within the Registry.
Recommended Action: Please refer to HP Document 'Managing the System Registry
Hive for Windows 2003 and Windows 2008 Integrity Systems' for information on
how to proactively manage this event type. This document can be found on
www.hp.com or at the following FTP location:
ftp://ftp.hp.com/pub/servers/software/WindowsIntegrity/ManagingWindowsRegistry.pdf.
WBEM EventID: 8313. WBEM ProviderName: FPL_IndicationProvider.Warning13783
System Hive size exceeds critical threshold. Probable Cause: This system has exceeded
the Upper threshold for the System Hive size within the Registry. Urgent action is
required in order to mitigate a potential failure to boot, should the System Hive
exceed 32Mb. Recommended Action: Refer to HP Document 'Managing the System
Registry Hive for Windows 2003 and Windows 2008 Integrity Systems' for information
on how to reduce the System Hive size and minimize risk of boot failure. This
document can be found on www.hp.com or at the following FTP location:
ftp://ftp.hp.com/pub/servers/software/WindowsIntegrity/ManagingWindowsRegistry.pdf.
WBEM EventID: 8314. WBEM ProviderName: FPL_IndicationProvider.Error13784
Detected a IOH QPI link's operation is degraded. Probable Cause: QPI link hardware
has been detected operating with degraded performance. Recommended Action:
Reboot. If problem persists contact support. WBEM EventID: 8480. WBEM
ProviderName: FPL_IndicationProvider.Warning13786
The system has been issued an INIT. All activity will be halted. Probable Cause: A
user has issued an INIT interrupt to the system. Recommended Action: None. The
system will restart on its own. WBEM EventID: 8495. WBEM ProviderName:
FPL_IndicationProvider.Error13874
Insufficient power; more power supplies may be needed. Probable Cause: Power
request to OA denied with the reason insufficient power. Either not enough BPS, or
too much power draw from other blades installed in enclosure. Consult OA to
determine if there is enough room to add BPS. Recommended Action: Install more
power supply units, or reduce the current draw on the power system. Power Cap is
one method that could be used to reduce current draw. You may want to verify that
none of your BPS have failed. WBEM EventID: 9866. WBEM ProviderName:
FPL_IndicationProvider.Error13877
The EM has determined that power must be shed and has asserted Power Alert.
Probable Cause: Typically caused by a power supply failure reducing the power pool
available to the EM to distribute to the blades. Recommended Action: Identify any
failed power supplies and replace them. WBEM EventID: 8502. WBEM ProviderName:
FPL_IndicationProvider.Warning13904
iLO entering special mode. Probable Cause: iLO entering special mode. The system
is not operating in a normal mode. Some protection features may be disabled in this
mode. Recommended Action: The special mode must be exited to ensure proper
operation of the server. WBEM EventID: 8503. WBEM ProviderName:
FPL_IndicationProvider.Warning13934
A firmware update has failed. Probable Cause: An attempted firmware update has
failed with an error. Recommended Action: Check to make sure that the bits are
accessible and system power is off. Try the update again. WBEM EventID: 8509.
WBEM ProviderName: FPL_IndicationProvider.Warning13979
A failure has occurred while attempting to update the iLO ROM. Probable Cause:
Something has interfered with firmware update while it attempted to update the bits
in the iLO ROM. Recommended Action: DO NOT REMOVE POWER FROM THE
SYSTEM. DO NOT RESET iLO. Attempt the update again or attempt update to
original version. Refer to recipe notes to verify no procedural issues. WBEM EventID:
8510. WBEM ProviderName: FPL_IndicationProvider.Error13980
A failure has occurred while attempting to update the SFW ROM. Probable Cause:
Something has interfered with firmware update while it attempted to update the bits
in the SFW ROM. The Aux ROM and either of the direct attach SFW ROMs or any
combination there of may be affected. Recommended Action: Attempt the update
again. If this fails you may want to reset iLO or remove stby power from the system
and try the update again. WBEM EventID: 8511. WBEM ProviderName:
FPL_IndicationProvider.Error13981
94 WBEM Provider Event Tables