HP Insight Management WBEM Provider Events Reference Guide

Core Analysis Engine received an unknown error log. WBEM EventID: 10446. WBEM
ProviderName: FPL_IndicationProvider.Warning14322
Core Analysis Engine failed to get error log bundle status. WBEM EventID: 10447.
WBEM ProviderName: FPL_IndicationProvider.Warning14323
Core Analysis Engine failed to get next error log bundle. WBEM EventID: 10448.
WBEM ProviderName: FPL_IndicationProvider.Warning14324
Core Analysis Engine failed to get the last processed bundle. WBEM EventID: 10449.
WBEM ProviderName: FPL_IndicationProvider.Warning14325
Core Analysis Engine failed to get the error log bundle status. WBEM EventID: 10450.
WBEM ProviderName: FPL_IndicationProvider.Warning14326
Invalid count reported for number of supported CPU p-states. Probable Cause: The
processor is reporting invalid data about its power management information.
Recommended Action: Verify that Firmware is at the current supported revision.
Replace the processor module. WBEM EventID: 9884. WBEM ProviderName:
FPL_IndicationProvider.Warning14415
Indicates an error has occurred while trying to reset SAS controllers. Probable Cause:
An error has occurred while trying to reset the SAS controller after a GMCA, during
I/O discovery or during early IOH Init. Recommended Action: Verify card is properly
seated. Update firmware on SAS controller. Verify that the system firmware is at a
supported revision. If problem persists, contact support. WBEM EventID: 9920.
WBEM ProviderName: FPL_IndicationProvider.Warning14431
System firmware failed to publish ACPI tables. Probable Cause: The ACPI subsystem
could not publish ACPI tables due to a System Firmware error. Recommended Action:
Verify that Firmware is at the current supported revision. WBEM EventID: 9874.
WBEM ProviderName: FPL_IndicationProvider.Error14441
Indicates an inconstency in bus numbering has been discovered. Probable Cause:
The busnumber returned by GetSystemSocketsInfo() does not match what is expected.
Recommended Action: Ensure all systems in the enclosure are conjoined as required
and functioning. Verify the SBL is installed and seated properly. Verify that MFW
and SFW on each blade is up-to-date. If problem persists, contact support. WBEM
EventID: 9928. WBEM ProviderName: FPL_IndicationProvider.Error14444
software memory test failed. Probable Cause: Unexpected data accessed from the
memory address during firmware memory test. Recommended Action: Check for
de-allocated DIMM(s). Reseat the DIMM(s). If the problem persists, then replace the
DIMM(s) with supported DIMM(s) - See Service Guide. WBEM EventID: 9875. WBEM
ProviderName: FPL_IndicationProvider.Warning14447
Scalable memory buffer (SMB) link initialization failed. Probable Cause: Scalable
Memory Buffer (SMB) link initialization failed. Recommended Action: Replace the
CPU. If problem still continues to exist, replace the system board. WBEM EventID:
9876. WBEM ProviderName: FPL_IndicationProvider.Warning14450
Scalable memory buffer (SMB) channel training failed. Probable Cause: Scalable
Memory Buffer (SMB) channel training failed. Recommended Action: The first action
will be to reset the CPU. If that does not solve the issue, replace CPU. If problem still
continues to exist, replace the system board. WBEM EventID: 9877. WBEM
ProviderName: FPL_IndicationProvider.Warning14451
Memory build-in self test (MBIST) failed. Probable Cause: Memory Build-in self test
failed. Recommended Action: The first action will be to check the SEL for the
de-allocated DIMM(s). Next, reseat the failing DIMM(s). If that does not solve the
issue, replace the DIMM(s) with supported DIMM(s) - See Service Guide. If problem
still continues to exist, replace the system board. WBEM EventID: 9880. WBEM
ProviderName: FPL_IndicationProvider.Warning14452
Memory build-in self test failed with timeout. Probable Cause: Memory built-in self
test failed with timeout. Recommended Action: The first action will be to check the
SEL for the de-allocated DIMM(s). Next, reseat the failing DIMM(s). If that does not
solve the issue, replace the DIMM(s) with supported DIMM(s) - See Service Guide.
If problem still continues to exist, replace the system board. WBEM EventID: 9881.
WBEM ProviderName: FPL_IndicationProvider.Warning14453