HP Insight Management WBEM Provider Events Reference Guide

DIMM rank mismatch or rank not found during memory initialization. Probable
Cause: The DIMM rank data is invalid or does not match with the other DIMM pair.
The DIMM FRU data is invalid and FW cannot initialize DIMMs based on invalid
data. Recommended Action: Reseat the DIMM. If problem persists, replace DIMM
with supported DIMM type (see Service Guide). WBEM EventID: 9882. WBEM
ProviderName: FPL_IndicationProvider.Warning14455
Unable to aquire communications link to scalable memory buffer (SMB). Probable
Cause: Failed to acquire communication link to scalable memory buffer (SMB).
Recommended Action: Reseat and/or replace the CPU. If problem still continues to
exist, replace the system board. WBEM EventID: 9883. WBEM ProviderName:
FPL_IndicationProvider.Warning14456
Failed outband read access to scalable memory buffer (SMB) due to timeout. Probable
Cause: Failed outband read access to Scalable Memory Buffer (SMB) due to timeout.
Recommended Action: Reseat/ replace the CPU. If problem still continues to exist,
replace the system board. WBEM EventID: 9878. WBEM ProviderName:
FPL_IndicationProvider.Warning14459
Failed outband write access to scalable memory buffer (SMB) due to timeout. Probable
Cause: Failed outband write access to Scalable Memory Buffer (SMB) due to timeout.
Recommended Action: Reseat and/or replace the CPU. If problem still continues to
exist, replace the system board. WBEM EventID: 9879. WBEM ProviderName:
FPL_IndicationProvider.Warning14460
Inband access to memory controller timed out. Probable Cause: Failed inband access
to Scalable Memory Buffer (SMB) due to timeout. Recommended Action: The first
action will be to reseat and/or replace the CPU. If problem still continues to exist,
replace the system board. WBEM EventID: 9890. WBEM ProviderName:
FPL_IndicationProvider.Warning14463
Frequency ratio for DIMM is incompatible. Probable Cause: Memory frequency ratio
is not supported by system platform. Recommended Action: The first action will be
to verify the suspect DIMM via iLO. Replace the DIMM with supported DIMM type
(see Service Guide). WBEM EventID: 9891. WBEM ProviderName:
FPL_IndicationProvider.Warning14464
Reached unexpected code paths in memory initialization code. Probable Cause:
Reached unexpected code paths in memory initialization code. Recommended Action:
Ensure FW is at the current supported revision. WBEM EventID: 9892. WBEM
ProviderName: FPL_IndicationProvider.Warning14465
LAI expander detected. Probable Cause: Unsupported memory Logical Analyzer
Interface (LAI) expander detected. Recommended Action: Contact support. WBEM
EventID: 9893. WBEM ProviderName: FPL_IndicationProvider.Warning14466
Invalid DIMM detected. Probable Cause: Invalid DIMM data found. Recommended
Action: Verify DIMM is supported type (See Service Guide). Reseat the DIMM. If
that does not solve the issue, replace DIMM. WBEM EventID: 9897. WBEM
ProviderName: FPL_IndicationProvider.Warning14467
DDR calibration for commands failed. Probable Cause: DDR calibration of command
failed. Recommended Action: The first action will be to check SEL for de-allocated
DIMM(s). Reseat and/or replace the DIMM(s). If that does not solve the issue, reseat
and/or replace CPU. If problem still continues to exist, replace the system board.
WBEM EventID: 9896. WBEM ProviderName: FPL_IndicationProvider.Warning14469
DDR channel training failed. Probable Cause: DDR training failure. Recommended
Action: The first action will be to check SEL for de-allocated DIMM(s). Reseat and/or
replace the DIMM(s). If that does not solve the issue, reseat and/or replace CPU. If
problem still continues to exist, replace system board. WBEM EventID: 9895. WBEM
ProviderName: FPL_IndicationProvider.Warning14470
Pre-initialization of memory controller failed. Probable Cause: Failed to initialize
internal communications engine on CPU. Recommended Action: The first action will
be to check SEL for de-allocated DIMM(s). Reseat and/or replace the DIMM(s). If that
does not solve the issue, reseat and/or replace CPU. WBEM EventID: 9894. WBEM
ProviderName: FPL_IndicationProvider.Warning14471
Platform Events 97