HP Integrity rx7640 and HP 9000 rp7440 Servers User Service Guide

Table 21 Front Panel LEDs (continued)
DescriptionStatusLED
FPGA detects no MPs present or functioningYellow
(solid)
Cell power onGreenCell 0 and Cell 1
(solid)
Cell power offOff
Cell fault. Cell powered off due to power problem or HPMC/MC
event from cell
Red
(solid)
Cell fault warningYellow
Latches not latched, LPM not ready, VRMs reporting not good or OT
Cell fan slow/failed
(flashing)
Cell not presentYellow (Solid)
User requests locator ON and specifies (1 - 72) hour off timeout.
Default timeout is 24 hours.
Blue
(flashing)
Locate
Timeout. Or user requests locator off.Off
Bulk Power Supply LEDs
There is a single three-color LED on each bulk power supply.
Figure 48 BPS LED Locations
Table 22 BPS LEDs
DescriptionLED Indication
BPS is in standby state with no faults or warningsBlinking Green
BPS is in run state (48 volt output enabled) with no faults or warningsGreen
BPS is in standby or run state with warning(s) present but no faultsBlinking Yellow
BPS is in standby state with recoverable fault(s) present but no non-recoverable faultsYellow
108 Server Troubleshooting