HP Integrity rx7640 and HP 9000 rp7440 Servers User Service Guide

Table 22 BPS LEDs (continued)
DescriptionLED Indication
BPS state might be unknown, non-recoverable fault(s) presentBlinking RED
Not UsedRed
BPS fault or failure, no power cords installed or no power to the chassisOff
PCI-X Power Supply LEDs
There are two active LEDs on the PCI-X power supply. A green power LED and a multi-color LED
reports warnings and faults.
Figure 49 PCI-X Power Supply LED Locations
Table 23 PCI-X Power Supply LEDs
DescriptionStateDriven ByLED
All output voltages generated by the power supply are
within limits.
On GreenEach supplyPower
1
Power to entire system has been removed.Off
The temperature within the power supply is above the lower
threshold.
Flash YellowEach supplyFault
2
The temperature of the power supply is approaching the
thermal limit.
On Yellow
Power supply has shut down due to an over temperature
condition, a failure to regulate the power within expected
limits, or a current-limit condition.
Flash Red
Normal operation.Off
System and PCI I/O Fan LEDs
There is a single three-color LED on each system and PCI I/O fan.
Server LED Indicators 109