HP Integrity rx7640 and HP 9000 rp7440 Servers User Service Guide
Figure 83 DVD Drive Location
Removing a Slimline DVD Drive
1. To remove the DVD drive, press the drive release mechanism to release the drive from the
drive bay.
2. Slide the drive out of the DVD carrier.
Replacing a Slimline DVD Drive
• Slide the drive into the DVD carrier until it clicks into place.
Removing and Replacing a Dual Slimline DVD Carrier
The Slimline DVD carrier is located in the front of the chassis. The system power to this component
must be removed before attempting to remove or replace it. See “Powering Off Hardware
Components and Powering On the Server” (page 126) for more information.
The carrier holds two Slimline DVDs. The carrier has 2 SCSI-to-IDE converter PCAs that enable the
Slimline DVDs to be hot-pluggable CRUs.
CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to follow
ESD safety precautions could result in damage to the server.
Removing and Replacing a Dual Slimline DVD Carrier 145