HP Integrity rx7640 and HP 9000 rp7440 Servers User Service Guide
Installing the Slimline DVD+RW Drives
1. Ensure the cables are the correct length. The black line on the SCSI cables and the red flags
on the red power cables must align with the front of the front bezel. See Figure 88.
IMPORTANT: The SCSI connectors must be on the right and the power cables must be on
the left when viewed from the front of the server for proper installation. See Figure 88. Cross
the power cables under the SCSI cables in the top of the server before the cables are inserted
into the drive bay
Figure 88 SCSI and Power Cables for Slimline DVD Installation
2. Connect the SCSI cables to the rear of the drive carrier. The SCSI cables are labeled to indicate
the top and bottom drives.
3. Connect the power cables to the rear of the drive carrier.
4. Install the left and right media rails and clips to the drive carrier.
5. Fold the cables out of the way and slide the drive carrier into the chassis.
a. The carrier easily slides into the chassis; however, a slow firm pressure is needed for
proper seating.
b. The front locking tab will latch to secure the carrier in the chassis.
6. Install the slimline drives into the carrier.
Removing and Replacing a PCI/PCI-X Card
The PCI/PCI-X cards are located in the rear of the chassis in the PCI-X card cage. PCI/PCI-X cards
are hot pluggable components.
CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to follow
ESD safety precautions could result in damage to the server.
Removing and Replacing a PCI/PCI-X Card 149