HP Integrity rx7640 and HP 9000 rp7440 Servers User Service Guide
Figure 14 Securing the Cabinet
Standalone and To-Be-Racked Systems
Servers shipped in a stand-alone or to-be-racked configuration must have the core I/O handles
and the PCI towel bars attached at system installation. Obtain and install the core I/O handles
and PCI towel bars from the accessory kit A6093-04046. The towel bars and handles are the
same part. See the following service note A6093A-11.
Rack-Mount System Installation
Information is available to help with rack-mounting the server. This list is intended to guide the HP
Installation Specialist to the documentation that has been written by the Rack and Power team. The
server can be installed in both the 10000 Series Rack and the Rack System/E.
The external Web site is:
http://h18004.www1.hp.com/products/servers/platforms/rackandpower.html
Lifting the Server Cabinet Manually
Use this procedure only if no HP approved lift is available.
CAUTION: This procedure must only be performed by four qualified HP Service Personnel utilizing
proper lifting techniques and procedures.
CAUTION: Observe all electrostatic discharge (ESD) safety precautions before attempting this
procedure. Failure to follow ESD safety precautions can result in damage to the server.
1. Follow the instructions on the outside of the service packaging to remove the banding and
cardboard top from the server pallet.
2. Reduce the weight by removing the bulk power supplies and cell boards. Place each on an
ESD approved surface.
CAUTION: System damage can occur through improper removal and reinstallation of bulk
power supplies and cell boards. See Chapter 6: Removing and Replacing Components, for
the correct procedures to remove and reinstall these components.
36 Installing the Server