HP Integrity rx7640 and HP 9000 rp7440 Servers User Service Guide

Figure 43 Example sa Command
5. Enter W to modify web access mode.
6. Enter option 2 to enable web access.
7. Launch a Web browser on the same subnet using the IP address for the MP LAN port.
Figure 44 Browser Window
8. Select the emulation type you want to use.
9. Click anywhere on the Zoom In/Out title bar to generate a full screen MP window.
10. Login to the MP when the login window appears.
Access to the MP via a Web browser is now possible.
Verifying the Presence of the Cell Boards
To perform this activity, either connect to the MP using a console, or connect the CE Tool (laptop)
to the RS-232 Local port on the MP/SCSI card.
68 Installing the Server