11BEthernet Teaming 136
Table 12-28 HP_AlertIndication: Full Redundancy Restored
Property name Property implementation
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Table 12-29 HP_AlterIndication: Connectivity Lost
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description If the Network Interface is an Ethernet Port, the Ethernet
Port has transitioned from OK to Error. If the Network
Interface is an Ethernet Team, the Ethernet Team has
transitioned from Fully Redundant, Degraded
Redundancy or Redundancy Lost to Overall Failure,
due to a failed team member.
AlertingManagedElement WBEM path of the Ethernet Port (HP_WinEthernetPort)
or Ethernet Team (HP_WinEthRedundancySet) reporting
lost connectivity.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 2 (Communications Alert)
Event Id 2
ProbableCause 7 (Other)
ProbableCauseDescription Network Interface Lost Connectivity
Provider Name Ethernet
RecommendedActions[] View the Ethernet and Ethernet Team Member status in
the HP Network Configuration Utility (NCU).
View the System Event Log for additional information.
SystemCreationClassName CreationClassName of the computer system generating
the indication