HP Insight Management WBEM Providers on Integrity Servers Data Sheet
12BSmart Array 170
Table 13-14 Class: HPSA_DAPort (CIM_DAPort)
Property name Property implementation
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_LogicalDevice
CreationClassName HPSA_DAPort
DeviceID Opaque key
SystemCreationClassName HPSA_ArraySystem
SystemName HPSA_ArraySystem.Name
CIM_LogicalPort
UsageRestriction 2 (Front-End Only)
CIM_DAPort
HPSA_DAPort
13-3-14 HPSA_SPIPort
HPSA_SPIPort represents the front-end port for an external Storage Subsystem. SPI implies that the
subsystem is connected through SCSI Parallel Interface to the Host.
Table 13-15 Class: HPSA_SPIPort (CIM_SPIPort)
Property name Property implementation
CIM_ManagedElement
ElementName Storage System name and location (for example,
MSA500 in SystemCab03)
CIM_ManagedSystemElement
OperationalStatus[0] Port status
• 0 (Unknown)
• 2 (OK)
• 6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_LogicalDevice