HP Insight Management WBEM Providers on Integrity Servers Data Sheet

12BSmart Array 175
Table 13-21 Class: HPSA_StorageSetting (CIM_StorageSetting)
Property name Property implementation
CIM_ManagedElement
ElementName RAID <n>, where <n> is the raid description
Examples:
RAID 0
RAID 1+0
RAID 5
RAID 6
CIM_SettingData
InstanceID Opaque key
CIM_StorageSetting
ChangeableType 0 (Not Changeable)
1 (RAID 0, RAID 5, RAID 6)
DataRedundancyGoal
2 (RAID 1+0)
1 (RAID 0, RAID 5, RAID 6)
DataRedundancyMax
2 (RAID 1+0)
1 (RAID 0, RAID 5, RAID 6)
DataRedundancyMin
2 (RAID 1+0)
DeltaReservationGoal 0
DeltaReservationMax 0
DeltaReservationMin 0
FALSE – RAID 0
NoSinglePointOfFailure
TRUE – RAID 1+0, RAID 5, RAID 6
0 (RAID 0)
PackageRedundancyGoal
1 (RAID 1+0, RAID 5)
2 (RAID 6)
0 (RAID 0)
PackageRedundancyMax
1 (RAID 1+0, RAID 5)
2 (RAID 6)
0 (RAID 0)
PackageRedundancyMin
1 (RAID 1+0, RAID 5)
2 (RAID 6)
HPSA_StorageSetting
13-3-21 HPSA_DriveCage
HPSA_DriveCage represents the drive cage assembly and back plane within a storage enclosure.
There can be multiple instances within a duplexed enclosure.