HP Insight Management WBEM Providers on Integrity Servers Data Sheet

12BSmart Array 183
Table 13-31 Class: HPSA_ArrayControllerLocation (HP_Location)
Property name Property implementation
ElementLocationTag for Internal HBAs: PCI Slot Number
Examples:
3 – for adapter in PCI Slot 3
0 – for Embedded adapter
For external controllers: Controller number per chassis
label
Examples:
Controller 1
Controller 2
23 (Adapter)—for Internal HBAs
ElementLocationTagDesc
1 (Hood Tag)—for External Controllers
LocationInformation[0] For internal HBAs: PCI Slot number
Examples:
3 – PCI Slot 3
0 – Embedded on Motherboard
Not required for External Storage Systems
3 (PCI Slot) – for internal HBAs
LocationInfoDesc[0]
Not required for External Storage Systems
HP_ArrayControllerLocation
13-3-31 HPSA_StorageCapabilities
HPSA_StorageCapabilities represents the possible capabilities of a Storage Pool.
Table 13-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities)
Property name Property implementation
CIM_ManagedElement
ElementName For Primodial Pools: Controller name and location
Examples:
Smart Array in Slot 3, for internal
Active Controller: MSA500 in SystemCab03, for
external
For Concrete Pools: Controller name and
location:Array identifier
Examples:
Smart Array in Slot 3: Array – 0, for internal
Active Controller: MSA500 in SystemCab03: Array
– 1, for external
CIM_Capabilities
InstanceID Key: Opaque key
CIM_StorageCapabilities