HP Insight Management WBEM Providers on Integrity Servers Data Sheet
12BSmart Array 197
Table 13-84 Class: HPSA_DiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation)
Property name Property implementation
Element HPSA_DiskPhysicalPackage
PhysicalLocation HPSA_DiskDriveLocation
13-3-84 HPSA_SCSIProtocolEndpointSCSIProtocolController
(Association)
Table 13-85 Class: HPSA_SCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement)
Property name Property implementation
AvailableSAP HPSA_SCSIProtocolEndpoint
ManagedElement HPSA_SCSIProtocolController
13-3-85 HPSA_StorageEnclosureEnclosureLocation (Association)
Table 13-86 Class: HPSA_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation)
Property name Property implementation
Element HPSA_StorageEnclosure
PhysicalLocation HPSA_StorageEnclosureLocation
13-4 Supported indications
Table 13-87 HPSA_DeviceIndication: Physical Drive status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description Physical Drive status has changed to a status of OK.
AlertingMangedElement WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)