HP Insight Management WBEM Providers on Integrity Servers Data Sheet

12BSmart Array 201
Table 13-88 HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name Property implementation
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Physical Disk firmware version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
Table 13-89 HPSA_DeviceIndication: Physical Drive status changed to REBUILDING
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description Physical Drive status has changed to a status of
Rebuilding. Data is now being rebuilt onto this drive
from the RAID set.
AlertingMangedElement WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1403
ProviderName SmartArray
RecommendedActions No action required.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication