HP Insight Management WBEM Providers on Integrity Servers Data Sheet
12BSmart Array 209
Table 13-92 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name Property implementation
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus Current OperationStatus values for Storage Volume
• DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
• DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
DeviceOperationalStatusPrevious Previous OperationStatus values for Storage Volume
• DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
• DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
Table 13-93 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description Logical Drive is in a degraded state. Device is still
servicing I/O but redundancy may be degraded or
lost.
AlertingMangedElement WBEM path of the HPSA_StorageVolume class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1203
ProviderName SmartArray
RecommendedActions Please allow time for recovery operation to complete.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical Drive is in a degraded state.