HP Insight Management WBEM Providers on Integrity Servers Data Sheet

14BSAS HBA 306
Table 15-71 HPSAS_DeviceIndication: SAS HBA status OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A SAS/SATA HBA status has changed from non-OK to
OK.
AlertingMangedElement WBEM Path of controller
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary HBA status OK
EventCategory 11 (I/O Adapter)
ProbableCause 1 (Other)
ProbableCauseDescription HBA Status Changed to OK
ProviderVersion 2.2.0.0
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
For Windows 2003 64-bit: 70
OSType
For Windows 2008 64-bit: 77
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication