HP Insight Management WBEM Providers on Integrity Servers Data Sheet

14BSAS HBA 322
Table 15-79 HPSAS_DeviceIndication: Logical Drive is in a degraded state
Property name Property implementation
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Table 15-80 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Subsystem status has
changed to non-redundant.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 301
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power Supply status Non-Redundant
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
Redundant