HP Insight Management WBEM Providers on Integrity Servers Data Sheet

15BSCSI HBA 374
Table 16-65 HPSCSI_DeviceIndication: Physical Drive status OFFLINE
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
Table 16-66 HPSCSI_DeviceIndication: Physical Drive status - Missing was OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive that was located in the system and
had a status of OK has been removed
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 9
ProviderName SCSIHBA
RecommendedActions Check for removal of this disk.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary The Physical Drive missing was OK.
EventCategory 6 (Primary Storage)
ProbableCause 73 (Element Missing)
ProbableCauseDescription Missing Physical Drive was OK.
ProviderVersion 2.2.0.0