Table 16-71 HPSCSI_DeviceIndication: Controller status OK
Property name Property implementation
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Controller firmware version string
HWLogicalLocation Controller Location string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
Table 16-72 HPSCSI_DeviceIndication: Controller status ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description SCSI HBA has failed and is no longer operating
AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class
instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName SCSIHBA
RecommendedActions Replace this HBA.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary This SCSI HBA has failed
EventCategory 11 (I/O Adapter)
ProbableCause 1 (other)