HP Insight Management WBEM Providers on Integrity Servers Data Sheet
15BSCSI HBA 386
Table 16-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description This SCSI Storage enclosure power supply was
redundant but due to a failure is not longer redundant
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 22
ProviderName SCSIHBA
RecommendedActions Replace failed or missing power supply module
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary SCSI Storage Enclosure operating with no Redundant
Power Supply
EventCategory 17 (Primary Storage Power)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
Redundant
ProviderVersion 2.2.0.0
NetworkAddresses A list of all the IP addresses of the computer system
generating the indication
• For Windows 2003 64-bit: 70
OSType
• For Windows 2008 64-bit: 77
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication