HP Insight Management WBEM Providers on Integrity Servers Data Sheet
15BSCSI HBA 387
Table 16-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT
Property name Property implementation
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
• 3 (Enclosure) for c-Class blade systems
ImpactedDomain
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Enclosure firmware version string
HWLogicalLocation Enclosure Location string
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
Table 16-74 HPSCSI_DeviceIndication: Power Supply status OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description All component power supplies that make up the
redundant power supply are in normal working order.