HP Insight Management WBEM Providers on Integrity Servers Data Sheet

3BSystem Power Supply 43
4 System Power Supply
4-1 Overview
This provider implements the HP Power Supply profile to model power supplies in Integrity systems.
The following profiles are implemented, and the following files are installed by this provider.
Table 4-1 Overview
HP Power Supply Profile 1.0
Implemented Profiles
HP Location Profile 1.0
HPWmiSensor.DLL
Provider Installation Files
HPWmiSensorEvt.DLL
HPWmiSensorEvtMsg.DLL
HPWmiSensor.mof
HPHlthEvtCons.mof
HPErrorMetaInstance.mof
HPWmiEvent.mof
HPWmiEvtCons.mof
HP_Sensor.mof
4-2 Use cases
For user cases, see the HP Power Supply Profile.
4-3 Class implementations
Classes and properties are implemented as specified in the following tables for Integrity server
platforms where available. The following classes describe power supplies.
4-3-1 HP_PowerSupply
HP_PowerSupply is used to model power supplies on Integrity Servers. The Windows-specific
implementation class is HP_WinPowerSupply. The power supply numbers for existing instances do not
change when other power supplies are added and removed.
Table 4-2 Class: HP_PowerSupply
Property name Property implementation
CIM_ManagedElement
Caption Power Supply n, where n represents the number of the
power supply instances.