HP Insight Management WBEM Providers on Integrity Servers Data Sheet
3BSystem Power Supply 45
Table 4-3 Class: HP_PowerCollection
Property name Property implementation
CIM_ManagedElement
Caption Power Collection
Description This is a collection of all devices including power
supplies that provide power. GroupStatusDescription.
GroupStatusDescription represents the value of the
GroupStatusDescriptions[0] property
ElementName Power Collection
CIM_SystemSpecificCollection
InstanceID Unique identifier for this power collection instance
HP_GroupSystemSpecificCollection
GroupOperationalStatus[0] Represents the most severe power redundancy status
and non-fault tolerant power supply operational status:
• 0 (Unknown) —If power collection status is
unknown
• 2 (OK) —If power supplies are operating properly
• 3 (Degraded) —If no
HP_WinPowerSupply.OperationalStatus[0] for all
non-fault tolerant power supplies report 6 (Error)
and
HP_WinPowerRedundancySet.RedundancyStatus
for any power redundancy sets report 3 (Degraded
Redundancy) or 4 (Redundancy Lost) and no power
redundancy sets report 5 (Overall Failure). If the
system starts up with a redundancy status set to 4
(Redundancy Lost) and no power supplies were
removed or failed, GroupOperationalStatus is set
to 2 (OK) because this is a valid configuration.
• 6 (Error) —If
HP_WinPowerSupply.OperationalStatus[0] for any
non-fault tolerant power supplies report 6 (Error) or
if HP_WinPowerRedundancySet.RedundancyStatus
for any power redundancy sets report 5 (Overall
Failure).
• Unknown status for power supplies, if
GroupOperationalStatus[0] is 0 (Unknown)
GroupStatusDescriptions[0]
• Power supplies are operating properly, if
GroupOperationalStatus[0] is 2 (OK)
• Fault tolerant power supplies are degraded, if
GroupOperationalStatus[0] is 3 (Degraded)
• Power supplies have failed, if
GroupOperationalStatus[0] is 6 (Error)