HP Insight Management WBEM Providers on Integrity Servers Data Sheet
3BSystem Power Supply 46
4-3-3 HP_PowerRedundancySet
HP_PowerRedundancySet is used to model power supply redundancy sets on Integrity servers. The
Windows implementation class is HP_WinPowerRedundancySet.
Table 4-4 Class: HP_PowerRedundancySet
Property name Property implementation
CIM_ManagedElement
Caption Power Redundancy Set n, where n represents the
number of the redundancy set instance
Description Power Redundancy Set n is collection of fault tolerant
power supplies that provide redundant power.
n represents the number of the redundancy set instance
ElementName Power Redundancy Set n, where n represents the
number of the redundancy set instance
CIM_SystemSpecificCollection
InstanceID Unique identifier for this power redundancy instance
CIM_RedundancySet
MaxNumberSupported The maximum number of power supplies supported for
this redundancy set
MinNumberNeeded The minimum number of power supplies needed to
function
TypeOfSet 3 (Load Balanced)
LoadBalanceAlgorithm 0 (Unknown)
• 0 (Unknown) – if the redundancy status is unknown
RedundancyStatus
• 2 (Fully Redundant) – if the all power supplies in
the set are operating properly and enough to
achieve redundancy
• 3 (Degraded Redundancy) – if there are at least
enough power supplies for the redundancy set to
provide power, but power supplies have failed
• 4 (Redundancy Lost) – if there are not enough
power supplies required to achieve redundancy,
but there are enough for the redundancy set to
provide power
• 5 (Overall Failure) – if there are not enough power
supplies operating properly for the redundancy set
to provide power.
4-3-4 HP_MemberOfPowerRedundancy
HP_MemberOfPowerRedundancy is used to represent an association between HP_PowerSupply and
HP_PowerRedundancySet. The Windows implementation class is
HP_WinMemberOfPowerRedundancy.