HP Insight Management WBEM Providers on Integrity Servers Data Sheet
4BSystem fan 52
Table 5-2 Class: HP_Fan
Property name Property implementation
Description Fan n provides cooling for fantype. statusdescription.
n represents the number of the fan instance, fantype
represents the corresponding string value of the
FanType enumeration and statusdescription represents
the value of StatusDescriptions[0]
ElementName Fan n, where n represents the number of the fan
instance.
CIM_ManagedSystemElement
• 2 (OK)—if fan is operating properly;
OperationalStatus[0]
• 6 (Error)—if fan has failed
• Fan is operating properly—if OperationalStatus[0]
is 2 (OK)
StatusDescriptions[0]
• Fan has failed—if OperationalStatus is 6 (Error)
• 5 (OK)—if fan is operating properly
HealthState
• 20 (Major Failure)—if fan has failed
Name Fan n, where n represents the number of the fan
instance.
CIM_LogicalDevice
CreationClassName HP_WinFan
DeviceID Unique identifier for this fan instance
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName HP_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_CoolingDevice
ActiveCooling True
CIM_Fan
• True—if fan supports variable speed
VariableSpeed
• False—if fan does not support variable speed or is
unknown
HP_Fan
FanType Enumeration describing the type of fan (see MOF)