HP Insight Manager WBEM Provider Events Reference
HP System Management Homepage Events
Source in Windows Event Log: HP System Management Homepage
Event DescriptionEvent SeverityEvent ID
The HP System Management Homepage Win32 service has been started successfully.Informational9
The HP System Management Homepage Win32 service has been stopped successfully.Informational10
The HP System Management Homepage Win32 service could not be started
successfully.
Error11
The HP System Management Homepage Win32 service could not be stopped
successfully.
Error12
MCA Events
Source in Windows Event Log: HpInsightMgmtProvs
Event DescriptionEvent SeverityEvent ID
%1 Failed to initialize service: %2. %3 %1 - "[component name]" %2 - "Error code =
error code" %3 - "See log file for details."
Error106
%1 Could not register with the Service Control Manager. %2 %1 - "[component name]"
%2 - "See log file for details.
Error113
%1 Could not set the service status with the Service Control Manager. %2 %1 -
"[component name]" %2 - "See log file for details.
Error114
%1 WMI usage error. %2 %1 - "[component name]" %2 - "See log file for details.Error126
PFM Events
Source in Windows Event Log: HpPfmSvcEx (for Event IDs 1 and 2)
Source in Windows Event Log: HpInsightMgmtProvs (for Event ID 107)
Event DescriptionEvent SeverityEvent ID
A Corrected Machine Check (or Corrected Platform Error) error of an unknown
variety was observed by the PreFail Monitor. This error was corrected and no action
is necessary, but if this condition repeats contact HP for support guidance.
Warning1
HP PFM has detected an invalid HP PFM rules file. As the result, default monitoring
threshold values are being used. Please contact HP support team to solve this problem.
Warning1
HP PFM service detected the DIMM module in %s has been added.Informational2
HP PFM service detected the DIMM module in %s has been removed.Informational2
HP PFM service detected the DIMM module in %s has been replaced.Informational2
HP PFM has detected a module replacement: The DIMM %s has been replaced. The
serial number of the older module was %s and the serial number of the newer is %s.
Informational2
HP PFM service detected the CPU module in %s has been added.Informational2
HP PFM service detected the CPU module in %s has been removed.Informational2
HP PFM service detected the CPU module in %s has been replaced.Informational2
HP PFM has detected a module replacement: The CPU %s has been replaced. The
serial number of the older module was %s and the serial number of the newer is %s.
Informational2
%1 Failed to initialize API: %2. %3 %1 - "[component name]" %2 - "EventApi" %3 -
"See log file for details."
Error107
HP System Management Homepage Events 105