HP Insight Manager WBEM Provider Events Reference
HP BMC IPMI Driver Events
Source in Windows Event Log: hpipmi
Event DescriptionEvent SeverityEvent ID
During communication with the IPMI BMC device, the system detected that the BMC
entered an error state. The driver attempted to set the BMC state to a working state
but failed to do so. After 20 successive attempts, the driver has set the IPMI device
to a non working state. It is recommended that you seek assistance from
Hewlett-Packard. You can return the device instance to the working state by disabling
and enabling the IPMI device instance labeled Hewlett-Packard IPMI Device. You
can locate the IPMI device instance within the Device Manager user interface.
Error
1000
A IPMI device was not recognized or detected, the IPMI device driver was not loaded.Error1001
The IPMI driver read a registry parameter that was invalid, the driver used a default
value for the registry parameter
HKLM\SYSTEM\CurrentControlSet\Control\IPMI\%2.
Warning
1002
The IPMI device driver attempted to communicate with the IPMI BMC device during
device creation. However the communication failed due to a timeout. Either the
configured timeouts are too small and the IPMI BMC device responses take longer
than the timeouts or the BMC has a technical fault. You can increase the timeouts
associated with the IPMI device driver.
Error
1003
The IPMI device driver attempted to communicate with the IPMI BMC device during
normal operation. However the communication failed due to a timeout. You can
increase the timeouts associated with the IPMI device driver located in the registry
at HKLM\SYSTEM\CurrentControlSet\Control\IPMI.
Error
1004
\Device\CpqHlth, The Hewlett Packard IPMI device driver was loaded.Informational2000
The Hewlett Packard IPMI device driver could not load. NTSTATUS return code is
shown in data field.
Error
2001
The IPMI device driver could not open the IML soft log in the windows registry: %2.Warning2002
hpWbemDump Events
Source in Windows Event Log: hpWbemDump
Event DescriptionEvent SeverityEvent ID
HP WBEM data was captured and compressed as a raw data format.%nOriginal
Size=%1, Compressed Size=%2, WMI Queries=%3, WMI Instances=%4, WMI
Properties=%5.%nAll succeeded.
Informational
1001
HP WBEM data was captured and compressed as a raw data format.%nOriginal
Size=%1, Compressed Size=%2, WMI Queries=%3, WMI Instances=%4, WMI
Properties=%5.%nFailed class List:%n%6
Warning
1002
HP WBEM system data was captured and compressed as a raw data
format.%nOriginal Size=%1, Compressed Size=%2, WMI Queries=%3, WMI
Instances=%4, WMI Properties=%5.%nAll succeeded.
Informational
1003
HP WBEM system data was captured and compressed as a raw data
format.%nOriginal Size=%1, Compressed Size=%2, WMI Queries=%3, WMI
Instances=%4, WMI Properties=%5.%nFailed class List:%n%6
Warning
1004
HP WBEM storage data was captured and compressed as a raw data
format.%nOriginal Size=%1, Compressed Size=%2, WMI Queries=%3, WMI
Instances=%4, WMI Properties=%5.%nAll succeeded.
Informational
1005
HP WBEM storage data was captured and compressed as a raw data
format.%nOriginal Size=%1, Compressed Size=%2, WMI Queries=%3, WMI
Instances=%4, WMI Properties=%5.%nFailed class List:%n%6
Warning
1006
106 WBEM Provider Event Tables