HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
A temperature inside the server went far outside the factory specified range. Probable
Cause: The temperature inside the server has gone far outside the factory specified
range for normal operation. To avoid permanent damage to your server hardware,
go and turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors Recommended Action: Find cause of temperature
anomaly and fix it. WBEM EventID: 753. WBEM ProviderName:
FPL_IndicationProvider02Error753
Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The
temperature inside the server has gone far outside the factory specified range for
normal operation. To avoid permanent damage to your server hardware, go and
turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors Recommended Action: Find cause of temperature
anomaly and fix it. WBEM EventID: 754. WBEM ProviderName:
FPL_IndicationProvider02Error754
One of the temperature sensors crossed its upper non-critical threshold. Probable
Cause: The temperature inside the server has gone outside the factory specified range
for normal operation. You should quit applications and power down the server to
protect its hardware from damage. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors Recommended Action: Find cause of temperature
anomaly and fix it. WBEM EventID: 755. WBEM ProviderName:
FPL_IndicationProvider02Warning755
A temperature inside the server went far outside the factory specified range. Probable
Cause: The temperature inside the server has gone far outside the factory specified
range for normal operation. To avoid permanent damage to your server hardware,
go and turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors Recommended Action: Find cause of temperature
anomaly and fix it. WBEM EventID: 756. WBEM ProviderName:
FPL_IndicationProvider02Error756
The AC voltage to the power supply was lost or is out of range. Probable Cause: The
AC voltage was lost, or is the wrong range for the system. Recommended Action:
Verify the power supply is plugged in to the proper voltage for the system. WBEM
EventID: 757. WBEM ProviderName: FPL_IndicationProvider02Warning757
The power supply AC voltage is out of range. Probable Cause: The AC voltage is
connected to the power supply, but it is not the voltage range required for the system.
Recommended Action: Connect the power supply to the proper voltage range. WBEM
EventID: 758. WBEM ProviderName: FPL_IndicationProvider02Warning758
Invalid OS INIT checksum. Probable Cause: OS has registered a bad OS_INIT vector
or the data has been lost. Recommended Action: Reboot system to allow vector to
be re-registered. WBEM EventID: 3450. WBEM ProviderName:
FPL_IndicationProviderWarning5001
Bad OS MCA checksum. Probable Cause: OS has registered a bad OS_MCA vector
or the data has been lost. Recommended Action: Reboot system to allow vector to
be re-registered. WBEM EventID: 200. WBEM ProviderName: FPL_IndicationProviderWarning5002
BMC interface to IPMI failed. Probable Cause: BMC firmware has locked up or the
BMC is disabled. Recommended Action: Cycle system power and attempt boot again.
If error re-occurs contact your HP representative for support. WBEM EventID: 201.
WBEM ProviderName: FPL_IndicationProviderWarning5003
12 WBEM Provider Event Tables