HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
Could not allocate memory for EFI image. Probable Cause: SFW could not allocate
enough memory for EFI image. Recommended Action: Reboot. If problem persists
contact your HP representative for support. WBEM EventID: 217. WBEM
ProviderName: FPL_IndicationProviderError5040
EFI image corrupted. Probable Cause: EFI image is corrupted. Recommended Action:
Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 218. WBEM ProviderName: FPL_IndicationProviderError5041
EFI not in fit table. Probable Cause: EFI image is not in FIT. Recommended Action:
Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 219. WBEM ProviderName: FPL_IndicationProviderError5042
NVRAM test fail. Probable Cause: NVM is corrupted or bad. Recommended Action:
Clear NVM, if problem persists contact your HP representative for support. WBEM
EventID: 220. WBEM ProviderName: FPL_IndicationProviderError5045
EFI Rom size bad. Probable Cause: EFI image is corrupt. Recommended Action:
Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 221. WBEM ProviderName: FPL_IndicationProviderError5048
EFI Rom checksum error. Probable Cause: EFI image is corrupt. Recommended
Action: Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 222. WBEM ProviderName: FPL_IndicationProviderError5049
External interruption nest limit exceeded. Probable Cause: Internal FW error.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 223. WBEM ProviderName: FPL_IndicationProviderError5050
External interrupt not serviced. Probable Cause: Internal FW error. Recommended
Action: Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 224. WBEM ProviderName: FPL_IndicationProviderError5051
Ext int taken. Probable Cause: An external interrupt has been taken Recommended
Action: Reboot. If problem persists contact your HP representative for support.
WBEM EventID: 225. WBEM ProviderName: FPL_IndicationProviderError5052
Forward Progress Log (FPL) access failed. Probable Cause: FPL access has failed,
possibly due to BMC communication interruption. SFW will not send any events to
the FPL until the system is rebooted. Recommended Action: Reboot or update System
and BMC FW. If problem persists contact your HP representative for support. WBEM
EventID: 226. WBEM ProviderName: FPL_IndicationProviderWarning5053
PSR fetch failure. Probable Cause: SFW tried to read the Processor Status Register
before the CPU data structure has been setup. Recommended Action: Reboot, if
problem persists contact your HP representative for support. WBEM EventID: 227.
WBEM ProviderName: FPL_IndicationProviderError5054
Cell halt. Probable Cause: Internal Error Recommended Action: contact your HP
representative for support. WBEM EventID: 228. WBEM ProviderName:
FPL_IndicationProviderError5055
CPU PAL incompatible with cpu. Probable Cause: Incompatible PAL. Recommended
Action: Update SFW or change processors WBEM EventID: 229. WBEM
ProviderName: FPL_IndicationProviderWarning5056
Slave is incompatible with monarch. Probable Cause: Incompatible processors.
Recommended Action: Replace processors. WBEM EventID: 230. WBEM
ProviderName: FPL_IndicationProviderWarning5057
Interrupt clear failure. Probable Cause: Interrupt clear failed. Recommended Action:
Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 231. WBEM ProviderName: FPL_IndicationProviderWarning5058
System Event Log (SEL) access failed. Probable Cause: An IPMI event has failed.
Recommended Action: Reset the BMC and reboot. If problem persists, contact HP
support to troubleshoot the problem. WBEM EventID: 232. WBEM ProviderName:
FPL_IndicationProviderWarning5059
14 WBEM Provider Event Tables