I/O host bridge inaccessible because rope reset failed to complete. Probable Cause:
I/O CEC failure. Recommended Action: Contact your HP representative to check the
I/O CEC. WBEM EventID: 276. WBEM ProviderName: FPL_IndicationProviderWarning5136
Insufficient power to turn on PCI slot. Probable Cause: The power budget for the IO
subsystem has been exceeded. Recommended Action: The IO config in the system
is unsupported. Verify that the IO config installed in the system is one that is
supported. If problem persists contact your HP representative for support. WBEM
EventID: 277. WBEM ProviderName: FPL_IndicationProviderWarning5137
PCI bus walk unknown error. Probable Cause: Internal firmware error. Recommended
Action: Contact your HP representative to check the firmware. WBEM EventID: 278.
WBEM ProviderName: FPL_IndicationProviderWarning5138
PCI bus walk resources exceeded. Probable Cause: Unsupported I/O configuration.
Recommended Action: Remove any unsupported I/O cards. Move the I/O card to
another slot. WBEM EventID: 279. WBEM ProviderName: FPL_IndicationProviderWarning5139
PCI bus unmap unknown error. Probable Cause: Internal firmware error.
Recommended Action: Contact your HP representative to check the firmware. WBEM
EventID: 280. WBEM ProviderName: FPL_IndicationProviderWarning5140
PCIXCAP sampling error. Probable Cause: I/O host bridge failure. Recommended
Action: Contact your HP representative to check the I/O host bridge. WBEM EventID:
281. WBEM ProviderName: FPL_IndicationProviderWarning5141
Power monitor failed to respond. Probable Cause: BMC failure. Recommended
Action: Contact your HP representative to check the BMC. WBEM EventID: 282.
WBEM ProviderName: FPL_IndicationProviderWarning5142
I/O rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended
Action: Reboot. If problem persists, contact your HP representative to check the I/O
controller. WBEM EventID: 283. WBEM ProviderName: FPL_IndicationProviderWarning5143
I/O SBA clear error failed. Probable Cause: I/O chipset failure. Recommended Action:
Contact your HP representative to check the I/O chipset. WBEM EventID: 284. WBEM
ProviderName: FPL_IndicationProviderWarning5144
PCI slot has incorrect default power state. Probable Cause: The hot-plug controller
has failed. Recommended Action: Contact your HP representative to check the
hot-plug slot. WBEM EventID: 285. WBEM ProviderName: FPL_IndicationProviderWarning5145
PCI slot power on error. Probable Cause: The I/O card is damaged or improperly
inserted. Recommended Action: Replace or reseat the I/O card. WBEM EventID: 286.
WBEM ProviderName: FPL_IndicationProviderWarning5146
PCI slot's standby power failed. Probable Cause: I/O slot failure. Recommended
Action: Reseat IO card. Replace IO card. If problem persists, contact your HP
representative to check the I/O slot. WBEM EventID: 287. WBEM ProviderName:
FPL_IndicationProviderWarning5147
Found invalid PCIXCAP value. Probable Cause: The I/O card is damaged or
improperly inserted. Recommended Action: Replace or reseat the I/O card. WBEM
EventID: 288. WBEM ProviderName: FPL_IndicationProviderWarning5148
Unsupported rope frequency. Probable Cause: Internal firmware error. Recommended
Action: Contact your HP representative to check the firmware. WBEM EventID: 289.
WBEM ProviderName: FPL_IndicationProviderWarning5149
Unsupported host bridge type. Probable Cause: Firmware needs to be updated. An
incorrect I/O backplane is installed. Recommended Action: Contact your HP
representative to check the firmware and the I/O backplane. WBEM EventID: 290.
WBEM ProviderName: FPL_IndicationProviderWarning5150
Machine Check initiated. Probable Cause: A Machine Check has occurred.
Recommended Action: Analyze cause of Machine Check using diag's and EFI tools.
WBEM EventID: 292. WBEM ProviderName: FPL_IndicationProviderError5152
18 WBEM Provider Event Tables