HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Memory ECC multiple-bit data error detection failed. Probable Cause: The CEC failed
MBE detection. Recommended Action: Contact HP support personnel to troubleshoot
the problem WBEM EventID: 307. WBEM ProviderName: FPL_IndicationProviderWarning5180
Memory ECC multiple-bit ECC error signalling failed. Probable Cause: The CEC
failed MBE detection. Recommended Action: Contact HP support personnel to
troubleshoot the problem WBEM EventID: 308. WBEM ProviderName:
FPL_IndicationProviderWarning5181
Memory ECC single-bit data error detection failed. Probable Cause: The CEC failed
SBE detection. Recommended Action: Contact HP support personnel to troubleshoot
the problem WBEM EventID: 309. WBEM ProviderName: FPL_IndicationProviderWarning5182
Memory ECC single-bit ECC error detection failed. Probable Cause: The CEC failed
SBE detection. Recommended Action: Contact HP support personnel to troubleshoot
the problem WBEM EventID: 310. WBEM ProviderName: FPL_IndicationProviderWarning5183
Insufficient memory for operation. Probable Cause: FW detected memory errors
below 1MB. Recommended Action: No action is needed if FW recovers. If system
will not boot, contact HP support to troubleshoot the problem. WBEM EventID: 311.
WBEM ProviderName: FPL_IndicationProviderWarning5185
Memory address not found in MBAT. Probable Cause: The address logged in the
CEC doesn't map to a memory rank, possibly due to a SFW error or NVM corruption
Recommended Action: Contact HP support to troubleshoot the problem. WBEM
EventID: 312. WBEM ProviderName: FPL_IndicationProviderWarning5186
Memory Error Information not cleared. Probable Cause: Software Error or CEC error
Recommended Action: Contact HP support to troubleshoot the problem WBEM
EventID: 313. WBEM ProviderName: FPL_IndicationProviderWarning5187
Couldn't clear memory error logs. Probable Cause: SFW Error or CEC error
Recommended Action: Contact HP support to troubleshoot the problem WBEM
EventID: 314. WBEM ProviderName: FPL_IndicationProviderWarning5189
Memory error clear failed. Probable Cause: SFW error or CEC error Recommended
Action: Contact HP support to troubleshoot the problem WBEM EventID: 315. WBEM
ProviderName: FPL_IndicationProviderWarning5190
DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM
is not loaded in order to allow for proper operation of the DIMM specified in the
physical location. Recommended Action: Refer to the user's manual for Memory
loading instructions. WBEM EventID: 316. WBEM ProviderName:
FPL_IndicationProviderWarning5191
Generic memory firmware error. Probable Cause: Corrupt NVM or System firmware
failure Recommended Action: Contact HP support to troubleshoot the problem.
WBEM EventID: 317. WBEM ProviderName: FPL_IndicationProviderWarning5193
Memory interleaving algorithm failed. Probable Cause: Unspecified WBEM EventID:
2903. WBEM ProviderName: FPL_IndicationProviderError5199
Memory interleave generation failed. Probable Cause: SFW is outdated. Recommended
Action: Update SFW. WBEM EventID: 318. WBEM ProviderName:
FPL_IndicationProviderError5202
Uncorrectable (multiple-bit) ECC error in DIMM. Probable Cause: Multiple bit error
in DIMM Recommended Action: Contact HP Support personnel to troubleshoot the
problem WBEM EventID: 2451. WBEM ProviderName: FPL_IndicationProviderWarning5204
Memory register test failed. Probable Cause: The register within the chipset went
bad. Recommended Action: Contact HP support to troubleshoot the problem WBEM
EventID: 319. WBEM ProviderName: FPL_IndicationProviderWarning5205
SPD found no memory DIMMs. Probable Cause: No DIMMs were detected
Recommended Action: Install DIMMs or Contact HP Support personnel to
troubleshoot the problem WBEM EventID: 320. WBEM ProviderName:
FPL_IndicationProviderError5208