HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
No memory found. Probable Cause: FW found memory, but it could not find a
correctly loaded rank. Recommended Action: Before this event is sent, FW will output
which ranks it is deallocating and why. Review the preceding events and refer to the
users manual to correct the memory loading. WBEM EventID: 321. WBEM
ProviderName: FPL_IndicationProviderError5209
Cannot log memory error because PDT is disabled. Probable Cause: FW found
memory errors during selftest, but could not deallocate the page because the PDT is
disabled. Recommended Action: Re-enable the PDT by clearing NVM WBEM EventID:
322. WBEM ProviderName: FPL_IndicationProviderError5211
PDT is disabled. Probable Cause: Informational event indicating that FW will not
use the PDT this boot. Recommended Action: No action is needed if user does not
want to use the PDT, otherwise, clear NVM WBEM EventID: 323. WBEM
ProviderName: FPL_IndicationProviderWarning5212
Error adding entry to PDT. Probable Cause: NVM write error. Recommended Action:
Contact HP support personnel to troubleshoot the problem. WBEM EventID: 324.
WBEM ProviderName: FPL_IndicationProviderWarning5214
Cannot add PDT entry-PDT full. Probable Cause: An attempt was made to add an
entry to a full PDT. Recommended Action: Run the 'pdt' command from the EFI shell
and remove/replace the DIMM that has the most PDT entries. If that doesn't work,
contact HP support. WBEM EventID: 1744. WBEM ProviderName:
FPL_IndicationProviderError5216
Memory platform data update failure. Probable Cause: Memory FW was unable to
save or restore the original error configuration. Recommended Action: If this is seen,
update SFW. WBEM EventID: 326. WBEM ProviderName: FPL_IndicationProviderWarning5218
Can't find memory rank entry. Probable Cause: The rank structure that corresponds
to the rankID in the data field could not be found in the Rank table, possibly due to
NVM corruption. Recommended Action: Contact HP support to troubleshoot the
problem. WBEM EventID: 327. WBEM ProviderName: FPL_IndicationProviderWarning5219
Memory error overflow:. Probable Cause: An error other than a memory error
occurred during the memory test Recommended Action: Contact HP support to
troubleshoot the problem WBEM EventID: 329. WBEM ProviderName:
FPL_IndicationProviderWarning5237
Memory forward progress code invalid. Probable Cause: The forward progress bits
are invalid. Recommended Action: Upgrade to latest system firmware, or contact
HP support to troubleshoot the problem. WBEM EventID: 330. WBEM ProviderName:
FPL_IndicationProviderWarning5238
Memory error status invalid. Probable Cause: Non-memory errors were detected
during the memory test that FW doesn't know how to handle. Recommended Action:
Update to the latest SFW Recommended Action: Contact HP support to troubleshoot
the problem. WBEM EventID: 331. WBEM ProviderName: FPL_IndicationProviderWarning5244
Memory error summary bits invalid. Probable Cause: The memory test summary
word is invalid Recommended Action: Update to the latest SFW. Recommended
Action: Contact HP support to troubleshoot the problem. WBEM EventID: 332. WBEM
ProviderName: FPL_IndicationProviderWarning5245
Unexpected machine check during memory code. Probable Cause: Incompatible
memory controller and memory DIMM. Recommended Action: Update system board
with current memory controller. WBEM EventID: 2685. WBEM ProviderName:
FPL_IndicationProviderError5248
The DIMM distribution check was bypassed. Probable Cause: Control bit to skip
DIMM distribution check is set. Recommended Action: Clear NVM Recommended
Action: Update PDC Recommended Action: Contact HP support to troubleshoot the
problem WBEM EventID: 333. WBEM ProviderName: FPL_IndicationProviderWarning5250