HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
The computed checksum for ESI Table incorrect. Probable Cause: Table corrupted.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 456. WBEM ProviderName: FPL_IndicationProviderError5700
ESI Table contains an unsupported entry type. Probable Cause: Corrupted table.
Recommended Action: Reboot system. If problem persists, contact HP support to
troubleshoot the problem. WBEM EventID: 457. WBEM ProviderName:
FPL_IndicationProviderWarning5701
A GUID was larger than the expected 128 bits. Probable Cause: Inconsistency in EFI
firmware. Recommended Action: Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem. WBEM EventID: 458. WBEM
ProviderName: FPL_IndicationProviderWarning5704
EFI is halting. Probable Cause: Unknown. Recommended Action: examine preceding
events for problem. WBEM EventID: 459. WBEM ProviderName:
FPL_IndicationProviderError5708
chipspare not supported on quad. Probable Cause: User installed a x8 DIMM in a
system configured for chipspare. Recommended Action: If user requires Chipspare,
replace the DIMM with a x4 DIMM. If Chipspare is not required, then no action is
required. WBEM EventID: 460. WBEM ProviderName: FPL_IndicationProviderWarning5711
EFI internal error detected resulting in execution of ASSERT macro. Probable Cause:
The cause is unknown. Recommended Action: Look at previous events and ASCII
information in this event for more information. If problem persists, contact HP support
to troubleshoot the problem. WBEM EventID: 461. WBEM ProviderName:
FPL_IndicationProviderWarning5712
EFI has executed the 'break' shell command. Probable Cause: Executing the 'break'
command. Recommended Action: Check for user entering 'break' command. Check
for shell scripts using the 'break' command. WBEM EventID: 462. WBEM
ProviderName: FPL_IndicationProviderError5713
EFI USB HCD interrupt service has detected the host controller is hung. Probable
Cause: Problem with USB controller. Recommended Action: Reset the card containing
the USB interface to restart the controller. Contact your HP representative to check
the USB interface. WBEM EventID: 463. WBEM ProviderName:
FPL_IndicationProviderError5714
The EFI/SAL handoff structure's version does not match EFI expectations. Probable
Cause: EFI/SAL firmware mismatch. Recommended Action: Reboot. If problem
persists contact your HP representative for support. WBEM EventID: 464. WBEM
ProviderName: FPL_IndicationProviderError5715
Unable to obtain access to all RTC SAL services. Probable Cause: Not all expected
services are available. Mismatch between EFI and SAL versions. Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 465. WBEM ProviderName: FPL_IndicationProviderError5717
Unable to obtain access to all SAL timer services. Probable Cause: Not all expected
services are available. Mismatch between EFI and SAL versions. Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 466. WBEM ProviderName: FPL_IndicationProviderError5718
EFI unable to start the periodic timer. Probable Cause: Internal system firmware
error. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 467. WBEM ProviderName:
FPL_IndicationProviderError5719
No I/O port space region found in the MDT. Probable Cause: EFI/SAL handoff
structure corrupted. Recommended Action: Reboot. If problem persists contact your
HP representative for support. WBEM EventID: 468. WBEM ProviderName:
FPL_IndicationProviderError5720
EFI reached an unimplemented section of code. Probable Cause: Reached
unimplemented firmware. Recommended Action: Upgrade system firmware. WBEM
EventID: 469. WBEM ProviderName: FPL_IndicationProviderError5721
32 WBEM Provider Event Tables