Event DescriptionEvent SeverityEvent ID
EFI unable to read current speedy boot settings. Probable Cause: BMC not functioning
properly. Recommended Action: Reset the BMC. Contact your HP representative to
check the BMC. WBEM EventID: 470. WBEM ProviderName: FPL_IndicationProviderWarning5722
Unpermitted SAL callback attempted. Probable Cause: Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 471. WBEM ProviderName: FPL_IndicationProviderError5723
EFI unable to determine frequency base of the CPU interval timer. Probable Cause:
Invalid timer ratio. Recommended Action: Reset system. WBEM EventID: 472. WBEM
ProviderName: FPL_IndicationProviderWarning5724
EFI system events already initialized. Probable Cause: Multiple attempts to initialize
system events, EFI internal error. Recommended Action: Upgrade system firmware.
If problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
473. WBEM ProviderName: FPL_IndicationProviderWarning5725
Unable to create internal virtualization event while initializing IPMI events. Probable
Cause: Out of resources. Internal EFI error. Recommended Action: Reboot system.
Upgrade system firmware. WBEM EventID: 474. WBEM ProviderName:
FPL_IndicationProviderWarning5726
There was an error creating or initializing the FPGA node in firmware. Probable
Cause: Unable to properly initialize a system firmware node Recommended Action:
Check for other errors in the system first. Invalidate NVM and retry to boot. Get the
latest firmware release. WBEM EventID: 476. WBEM ProviderName:
FPL_IndicationProviderError5728
Error creating the pdh ioconfig node or attaching the service to it. Probable Cause:
This is likely to be a symptom of an earlier problem, or the system is out of malloc
space. Recommended Action: Contact system firmware team. WBEM EventID: 1009.
WBEM ProviderName: FPL_IndicationProviderError5729
Error encountered setting up the dillon_pdh node or service. Probable Cause: This
is usually a symptom of an earlier problem. Check to be sure the pdh node was
initialized into the tree correctly. WBEM EventID: 1010. WBEM ProviderName:
FPL_IndicationProviderError5730
The PDH component encountered an error dealing with a property on a node.
Probable Cause: This is usually due to a memory allocation problem. Verify that
sram is usable and there is memory available. WBEM EventID: 2459. WBEM
ProviderName: FPL_IndicationProviderError5731
Error creating the acpi_hw node. Probable Cause: May be out of malloc space or a
previous tree error prevented this from being successful. Check for earlier errors.
WBEM EventID: 2460. WBEM ProviderName: FPL_IndicationProviderError5732
Error encountered creating or initializing the ipmi node. Probable Cause: Possibly
out of memory or an earlier error left the tree in an unusable state. WBEM EventID:
2461. WBEM ProviderName: FPL_IndicationProviderError5733
some processors not compatible. Probable Cause: Installed processors are not of
compatible models or families Recommended Action: Replace processors with
compatible ones if all processors are to be used. WBEM EventID: 481. WBEM
ProviderName: FPL_IndicationProviderError5734
caches sizes are inconsistent. Probable Cause: Processors with different cache sizes
are installed in the system. Recommended Action: Replace processors with compatible
ones if all processors are to be used. WBEM EventID: 482. WBEM ProviderName:
FPL_IndicationProviderError5735
selecting new monarch. Probable Cause: The monarch processor was not the lowest
stepping processor installed within the cell. Recommended Action: No action is
required. FW takes action automatically. To avoid this event, be sure that the monarch
processor is the lowest stepping of processor in the system. WBEM EventID: 484.
WBEM ProviderName: FPL_IndicationProviderWarning5737