HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
monarch not lowest stepping. Probable Cause: The monarch processor has a stepping
that is greater than a slave processor installed in the system. Recommended Action:
No action is needed. If problem persists, update System FW or contact your HP
representative for support. WBEM EventID: 485. WBEM ProviderName:
FPL_IndicationProviderWarning5738
processors are over clocked. Probable Cause: FSB speed faster than the capabilities
of the processors Recommended Action: If multiple CPU's report this issue, check
the BMC. If only one reports this issue, replace the CPU. If problem persists, contact
HP support. WBEM EventID: 487. WBEM ProviderName: FPL_IndicationProviderWarning5740
cpu access error on processor info area. Probable Cause: An early version of CPU or
a bad info ROM. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 488. WBEM ProviderName:
FPL_IndicationProviderWarning5741
PAL A was not executed - HALT. Probable Cause: PAL_A has not been executed.
Recommended Action: Contact your HP representative for support. WBEM EventID:
489. WBEM ProviderName: FPL_IndicationProviderError5742
PAL B was not executed - HALT. Probable Cause: PAL_B has not been executed.
Recommended Action: Contact your HP representative for support. WBEM EventID:
490. WBEM ProviderName: FPL_IndicationProviderError5743
Prototype CPU installed. Probable Cause: A Prototype CPU is installed. Recommended
Action: Replace CPU with a production CPU. WBEM EventID: 491. WBEM
ProviderName: FPL_IndicationProviderWarning5744
final boot rendezvous monarch watchdog timeout. Probable Cause: A watchdog
timer has expired and determined that a monarch is dead. Recommended Action:
Reboot, if problem persists, replace CPU. WBEM EventID: 492. WBEM ProviderName:
FPL_IndicationProviderWarning5745
Supplemental cpu tests generated an unexpected result. Probable Cause: A CPU
failed supplemental selftests. Replace the offending CPU. WBEM EventID: 2462.
WBEM ProviderName: FPL_IndicationProviderError5746
A multi-bit error was found while reading a XBC CSR. Probable Cause: Possibly bad
link or cell connection. Recommended Action: Reset partition, and check hardware
associated with event data. WBEM EventID: 493. WBEM ProviderName:
FPL_IndicationProviderWarning5747
The return value from a function was an unknown value. Probable Cause: Firmware
error Recommended Action: Reset cell WBEM EventID: 494. WBEM ProviderName:
FPL_IndicationProviderWarning5749
Cannot get system ID status from BMC. Probable Cause: Inaccessible FRU EPROM
on system board and/or I/O backplane. Failure in IPMI messaging path on system
board and/or I/O backplane Recommended Action: Check FRU EPROM content and
accessibility on system and I/O backplane using ifru. If BMC communication is not
working (no answer from BMC), flash BMC firmware. If it cannot be done or doesn't
solve the problem, replace system board. If system board FRU EPROM cannot be
accessed, replace system board If I/O backplane FRU EPROM cannot be accessed,
replace I/O backplane WBEM EventID: 495. WBEM ProviderName:
FPL_IndicationProviderWarning5750
Cannot read a system ID. Probable Cause: BMC failure Recommended Action: Unplug
power from the system for 10 seconds and try rebooting the system. WBEM EventID:
496. WBEM ProviderName: FPL_IndicationProviderWarning5751
Failed to write new system ID. BMC reported an error. Probable Cause:
Communication failure with the BMC. Recommended Action: Unplug power from
the system for 10 seconds and try rebooting the system. WBEM EventID: 497. WBEM
ProviderName: FPL_IndicationProviderWarning5752