HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
Unable to enter normal system mode because EFI/SAL interface not initialized.
Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware.
If problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
512. WBEM ProviderName: FPL_IndicationProviderWarning5771
Unable to initialize part of the SAL/EFI interface. Probable Cause: Incompatible
versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem
persists contact your HP representative for support. WBEM EventID: 513. WBEM
ProviderName: FPL_IndicationProviderError5772
An expected tree node was not found. Probable Cause: This is a bug. Contact
engineering. WBEM EventID: 515. WBEM ProviderName: FPL_IndicationProviderError5774
EFI unable to modify system state to 'running'. Probable Cause: BMC non functional.
Recommended Action: Contact your HP representative to check the BMC. WBEM
EventID: 516. WBEM ProviderName: FPL_IndicationProviderWarning5776
/options settings for CPUBusConfigValue aren't compatible with PAL. Probable
Cause: Update the /options value to comply with the desired features and what is
supported. WBEM EventID: 2433. WBEM ProviderName: FPL_IndicationProviderWarning5777
The Get Processor Bus Dependent Configuration Features PAL call failed. Probable
Cause: Contact engineering. There is a PAL compatibility problem. WBEM EventID:
518. WBEM ProviderName: FPL_IndicationProviderWarning5778
memory DIMM pair mismatch. Probable Cause: The user installed a mismatched
pair of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width).
Recommended Action: Install memory ranks in pairs of DIMMs that are the same
size and DRAM width. WBEM EventID: 519. WBEM ProviderName:
FPL_IndicationProviderWarning5779
EFI unable to initialize internal library. Probable Cause: Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 520. WBEM ProviderName: FPL_IndicationProviderError5784
EFI unable to initialize security system. Probable Cause: BMC not responding
properly. Recommended Action: Reset BMC. Contact your HP representative if
problem persists. WBEM EventID: 521. WBEM ProviderName:
FPL_IndicationProviderError5785
EFI detected invalid internal privilege level. Probable Cause: SAL storage corrupted.
Recommended Action: Reboot system. WBEM EventID: 522. WBEM ProviderName:
FPL_IndicationProviderWarning5786
EFI detected invalid privilege level when setting password. Probable Cause: Internal
EFI error. Recommended Action: Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem. WBEM EventID: 523. WBEM
ProviderName: FPL_IndicationProviderWarning5787
EFI MDT table is bad. Probable Cause: SFW has determined that the MDT table is
invalid. Recommended Action: Reboot or update System FW. If problem persists
contact your HP representative for support. WBEM EventID: 524. WBEM
ProviderName: FPL_IndicationProviderError5788
Processor has incompatible fixed core ratio. Probable Cause: A CPU has a fixed ratio
that is incompatible with the FSB frequency set in the chipset. Recommended Action:
Contact your HP representative for support. WBEM EventID: 525. WBEM
ProviderName: FPL_IndicationProviderWarning5790
All processors slated for compatibility deconfiguration. Probable Cause: The user or
SFW has set all CPUs to be deconfigured. Recommended Action: Look for events
indicating incompatible or bad CPUs and replace them. If problem persists contact
your HP representative for support. WBEM EventID: 526. WBEM ProviderName:
FPL_IndicationProviderError5791
36 WBEM Provider Event Tables