HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
The XBC neighbor chip number does not match the expected value for this topology.
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. WBEM EventID: 542. WBEM ProviderName: FPL_IndicationProviderError5809
The XBC neighbor port number does not match the expected value for this topology.
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. WBEM EventID: 543. WBEM ProviderName: FPL_IndicationProviderError5810
Write through to BMC token failed. Probable Cause: Problem accessing the BMC.
Recommended Action: Reset BMC or reboot. Upgrade BMC FW and System FW. If
problem persists, contact your HP representative for support. WBEM EventID: 544.
WBEM ProviderName: FPL_IndicationProviderWarning5811
Utilities reported an error while trying to manipulate the LED. Probable Cause: It is
likely the GSP is not present or the device specified is not present. Solve these
problems and try again. WBEM EventID: 2465. WBEM ProviderName:
FPL_IndicationProviderWarning5812
Duplicate Cpu Ids were detected within a cell. Probable Cause: Most likely cause is
a bad cpu module connection on the cell board. Replace the cell board. WBEM
EventID: 546. WBEM ProviderName: FPL_IndicationProviderError5813
OS crashdump started (D700). Probable Cause: panic occurred WBEM EventID: 547.
WBEM ProviderName: FPL_IndicationProviderWarning5823
OS legacy PA hex fault code (Bxxx). Probable Cause: fault/panic WBEM EventID:
548. WBEM ProviderName: FPL_IndicationProviderError5824
OS dump status (EFxx). Probable Cause: panic, mca, or INIT path: attempt to write
out the dump is complete Recommended Action: No action required WBEM EventID:
549. WBEM ProviderName: FPL_IndicationProviderWarning5825
Setting processor response timeout failed. Probable Cause: A PAL call made by SFW
has failed. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. WBEM EventID: 550. WBEM ProviderName:
FPL_IndicationProviderWarning5827
Unable to validate blank password during EFI security initialization. Probable Cause:
BMC failed. Recommended Action: Reset the BMC. Update BMC FW. Contact your
HP representative to check the BMC. WBEM EventID: 551. WBEM ProviderName:
FPL_IndicationProviderWarning5832
Unable to enter Guest mode during EFI security initialization. Probable Cause: BMC
failure. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP
representative to check the BMC. WBEM EventID: 552. WBEM ProviderName:
FPL_IndicationProviderWarning5833
Unable to increase privilege during EFI security initialization. Probable Cause: SAL
failure. Recommended Action: Reset the system. Upgrade system firmware. If problem
persists, contact HP support to troubleshoot the problem. WBEM EventID: 553.
WBEM ProviderName: FPL_IndicationProviderWarning5834
EFI unable to write privilege level during security initialization. Probable Cause:
SAL failure. Recommended Action: Reboot the system. Update SFW. If problem
persists, contact HP support to troubleshoot the problem. WBEM EventID: 554.
WBEM ProviderName: FPL_IndicationProviderWarning5836
EFI was denied permission to write the privilege level during security init. Probable
Cause: SAL is not in ADMIN or USER mode. Recommended Action: Reboot the
system. Upgrade system firmware. If problem persists, contact HP support to
troubleshoot the problem. WBEM EventID: 555. WBEM ProviderName:
FPL_IndicationProviderWarning5837
OS dump, error writing image area to disk (E055). Probable Cause: panic path forward
progress WBEM EventID: 556. WBEM ProviderName: FPL_IndicationProviderWarning5853
38 WBEM Provider Event Tables