HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Management Processor detected an I2C Communication Error with BMC. Probable
Cause: An I2C Communication failure with the Baseboard Management Controller
was detected. Without I2C communication, the system cannot be powered on/off or
reset. Check the I2C communication via the 'SR' command or the 'PS' command. If
it is indeed down, look for hardware reasons. It's possible resetting the Management
Processor firmware ('XD' command option 'r') or completely cycling AC power of
the system will restore the communication. WBEM EventID: 612. WBEM
ProviderName: FPL_IndicationProviderWarning7686
A CRC error was discovered when verifying the ROM. Probable Cause: Either the
ROM was programmed incorrectly or has gone bad. Reprogram the Flash on the cell
board. WBEM EventID: 613. WBEM ProviderName: FPL_IndicationProviderError7690
(HWE) IO backplane type unknown. Probable Cause: This is an alien IO backplane.
IO discovery will fail. I/O for the cell will not be initialized. Recommended Action:
Replace I/O backplane or chassis or update firmware. WBEM EventID: 1757. WBEM
ProviderName: FPL_IndicationProviderWarning7718
CPU Revisions did not match. Probable Cause: 2 cpus are at different revisions.
Replace incompatible cpu. WBEM EventID: 638. WBEM ProviderName:
FPL_IndicationProviderError7732
2 cpus are running at mismatched frequencies. Probable Cause: There is a CPU or
Cell compatibility problem. Verify that all cpus are clocked at the same frequency
and have the same ratios set. WBEM EventID: 639. WBEM ProviderName:
FPL_IndicationProviderError7733
A cpu is being overclocked. Probable Cause: A cpu is being clocked at a rate higher
than it is rated for. Replace the cpu or cell board. WBEM EventID: 640. WBEM
ProviderName: FPL_IndicationProviderError7734
Copy of complex profile on sub and cells don't match. Probable Cause: MP NVRAM
was erased by removing MP from system without setting 'NVRAM SAVE' switch to
on. MP was replaced with cabinet's AC Breakers 'off'. Either of first two causes and
replacing or installing a cell board with cabinet's AC Breakers 'off'. Recommended
Action: Remove cell board causing problem. Power complex on and allow cells to
distribute their copy of complex profile to MP, then add new cell following proper
OLA procedures. Remove improper cell board. Execute MP Handler 'CC' command
and choose 'Last Profile'. This will load the sub with what should be the same copy
as the cells. Then add new cell board. WBEM EventID: 641. WBEM ProviderName:
FPL_IndicationProviderError7758
Duplicate cabinet number detected. Probable Cause: When adding a new cabinet to
the complex or replacing the UGUY, the cabinet number switch was set to a number
already in use. Recommended Action: Turn off AC breakers to cabinet with duplicate
number. Check all other cabinet numbers in the complex for validity. Set cabinet
number switch on UGUY-PCB in new cabinet (s) to proper cabinet number. Turn on
AC breakers for cabinet(s). WBEM EventID: 642. WBEM ProviderName:
FPL_IndicationProviderError7760
MP ID command must be run. Probable Cause: This is the first time the machine has
been powered on and there is no valid complex profile anywhere. Recommended
Action: Run 'CC' command and generate genesis profile. WBEM EventID: 643. WBEM
ProviderName: FPL_IndicationProviderError7767
MP Battery is low. Probable Cause: MP was running on battery for too long. Someone
didn't set 'NVRAM Save' switch to 'off'. Recommended Action: Replace battery as
per MP Battery Remove and Replace procedures. WBEM EventID: 645. WBEM
ProviderName: FPL_IndicationProviderWarning7771