HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
1 Side Converter Over Temp. Probable Cause: If this code is not accompanied by
other codes pointing to the same Bulk Power Supply, then it is an internal component
failure. Recommended Action: Contact HP Support personnel to troubleshoot
problem. WBEM EventID: 2436. WBEM ProviderName: FPL_IndicationProviderWarning7796
Bulk Power Supplies are not Redundant. Probable Cause: Entities were added to the
cabinet, increasing the estimated Power Consumption. Or, a non-functional GSP bus
entity has become functional, providing previously missing power consumption
information. Recommended Action: Purchase and install a Bulk Power Supply, if
redundancy is desired. WBEM EventID: 659. WBEM ProviderName:
FPL_IndicationProviderWarning7798
+48V DC has exceeded its upper limit. Probable Cause: The cabinet's 48V power has
exceeded an acceptable upper threshold. Recommended Action: Contact HP Support
personnel to troubleshoot problem. WBEM EventID: 660. WBEM ProviderName:
FPL_IndicationProvError7799
+48V DC has fallen below its lower limit. Probable Cause: The cabinet's 48V power
has fallen below an acceptable lower threshold. Recommended Action: Contact HP
Support personnel to troubleshoot problem. WBEM EventID: 661. WBEM
ProviderName: FPL_IndicaError7803
Cabinet Fan Failed. Probable Cause: Cabinet Fan Failed Recommended Action:
Replace failed cabinet fan module as soon as possible following the Cabinet Fan
Module Remove and Replace Procedures. WBEM EventID: 662. WBEM ProviderName:
FPL_IndicationProviderWarning7806
Housekeeping power has exceeded expected levels. Probable Cause: The cabinet's
housekeeping power has risen above an acceptable upper threshold. Recommended
Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID:
670. WBEM ProviderName: FPL_IndicationProviderError7822
Housekeeping power has fallen below expected levels. Probable Cause: The cabinet's
housekeeping power has fallen below an acceptable upper threshold. Recommended
Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID:
671. WBEM ProviderName: FPL_IndicationProviderError7823
The BPSs for the cabinet are illegally configured. Data Byte 3 = PDCA number.
Probable Cause: The BPS are installed in an illegal configuration. Recommended
Action: Re-configure the BPS in a manner consistent with the explanation in the
Problem Description statement WBEM EventID: 672. WBEM ProviderName:
FPL_IndicationProviderWarning7824
BPS ID received from installed Bulk Power Supply was unknown. Probable Cause:
The designated power supply is responding with an illegal BPS ID. It could be a
faulty supply, a different revision, or a wrong supply in the wrong box. Recommended
Action: Replace this Bulk Power Supply with a proper one. WBEM EventID: 673.
WBEM ProviderName: FPL_IndicationProviderWarning7825
Ambient Air Sensor Overtemp Warning. Probable Cause: Room Temperature has
risen to a critical level. Recommended Action: Shutdown and power off the system.
Correct air temperature problem. WBEM EventID: 675. WBEM ProviderName:
FPL_IndicationProviderError7827
Ambient Air Sensor Overtemp Warning. Probable Cause: Room Temperature is
rising or falling. Recommended Action: Check the error log's previous entries within
a logical time frame. If temperature is rising, prepare for system shutdown. If
temperature is dropping, then problem is probably resolved. WBEM EventID: 676.
WBEM ProviderName: FPL_IndicationProviderWarning7828
Ambient Air Sensor Overtemp Warning. Probable Cause: Room Temperature is
rising or falling. Recommended Action: Check the error log's previous entries within
a logical time frame. If temperature is rising, prepare for system shutdown. If
temperature is dropping, then problem is probably resolved. WBEM EventID: 677.
WBEM ProviderName: FPL_IndicationProviderError7829
Platform Events 43