HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
IO Fan Failed. Probable Cause: IO Cooling Fan Failed Recommended Action: Replace
IO Fan Module as soon as possible following the IO Fan Module Remove and Replace
Procedures. WBEM EventID: 678. WBEM ProviderName: FPL_IndicationProviderWarning7836
Cabinet Power System is in overload. Probable Cause: A Bulk Power Supply has
failed, or, entities were added. Look for one or more BPS_Fail Chassis Codes preceding
this one for the actual failures. This code is a warning of possible cabinet unreliability.
Recommended Action: Contact HP Support personnel to troubleshoot the problem.
WBEM EventID: 680. WBEM ProviderName: FPL_IndicationProviderWarning7842
Cabinet Shutdown - Insufficient Blowers. Probable Cause: One blower has failed
creating condition N. Before condition N was corrected, another blower in the same
cabinet was declared failed. This created the illegal condition of N-1. Recommended
Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID:
681. WBEM ProviderName: FPL_IndicationProviderError7845
Cabinet Shutdown - Insufficient IO Fans. Probable Cause: One IO fan has failed
creating condition N. Before condition N was corrected, another IO fan in the same
cabinet failed. This created the illegal condition of N-1. Recommended Action: Contact
HP Support personnel to troubleshoot the problem WBEM EventID: 682. WBEM
ProviderName: FPL_IndicationProviderError7846
IO Expansion Utility Cabinet Fan Failed. Probable Cause: IO Expansion Utility Fan
or Fan sensor failure PM failure Recommended Action: Contact HP Support personnel
to troubleshoot the problem WBEM EventID: 683. WBEM ProviderName:
FPL_IndicationProviderWarning7849
Watchdog Timer Expired. Probable Cause: CLU has been reset after a firmware
update. Recommended Action: No action is required. WBEM EventID: 684. WBEM
ProviderName: FPL_IndicationProviderError7855
Invalid checksum from EEPROM. Probable Cause: Problem with I2C bus.
Recommended Action: If every entity with a FRUID logs an error, the problem is
probably with the CLU portion of the Utilities Board. Replace the Utilities Board
following the Utilities Board Remove and Replace Procedures. If there are a few
entities reporting checksum errors, but several have reported in properly, chances
are one device is causing the problem with the I2C bus. This will take a more concerted
effort to find and correct that problem. Probably wish to take the bus to a minimum
configuration and test, add, test until the failure is verified. WBEM EventID: 685.
WBEM ProviderName: FPL_IndicationProviderError7856
System Backplane Power Board Fault. Probable Cause: A DC-DC converter on the
named power board failed. Recommended Action: Contact HP Support personnel
to troubleshoot the problem Caution: The 1.8 volt converters are N+1. The 3.3 volt
converters are N+2. If there is a situation where a 1.8 fails at the same time as a 3.3
on a different power board, replace the failed 1.8 board first. WBEM EventID: 686.
WBEM ProviderName: FPL_IndicationProviderWarning7858
Read of EEPROM failed. Probable Cause: The I2C controller on the Utilities Board
(CLU section) is bad. This will be shown by many I2C failure codes in the Error Log.
These codes should identify entities on both the System Backplane and the Master
IO Backplane. Recommended Action: Contact HP Support personnel to troubleshoot
the problem. WBEM EventID: 687. WBEM ProviderName: FPL_IndicationProviderWarning7863
Read of EEPROM failed. Probable Cause: The cable from the Utilities Backplane to
the Master IO Backplane is bad, or is not properly connected. Recommended Action:
Check and reseat the Master IO Backplane Utilities cable. If no help, contact HP
Support personnel to troubleshoot the problem. WBEM EventID: 688. WBEM
ProviderName: FPL_IndicationProviderWarning7864
Read of LPM Fault failed. Probable Cause: The cable from the Utilities Backplane to
the Master IO Backplane is bad, or is not properly connected. Recommended Action:
Check and reseat the Master IO Backplane Utilities cable. If no help, contact HP
Support personnel to troubleshoot the problem. WBEM EventID: 689. WBEM
ProviderName: FPL_IndicationProviderWarning7865
44 WBEM Provider Event Tables