HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
System Backplane voltage margin failed. Probable Cause: The CLU was unable to
write to the voltage margin register on the System backplane. Recommended Action:
Try re-margining the system backplane and check connections. If many I2C access
events are occurring inspect the UGUY utilities board. WBEM EventID: 700. WBEM
ProviderName: FPL_IndicationProviderError7880
Failure to write data to FRUID EEPROM. Probable Cause: The entity being written
to has failed. Recommended Action: Replace the entity with the failed FRUID. WBEM
EventID: 701. WBEM ProviderName: FPL_IndicationProviderWarning7891
CPU fan failed. Probable Cause: The CPU fan identified by the attached physical
location has failed. Recommended Action: Contact HP Support personnel to
troubleshoot problem WBEM EventID: 2904. WBEM ProviderName:
FPL_IndicationProviderError7892
CPU fan failing. Probable Cause: The CPU fan identified by the attached physical
location is not operating at expected speed. Recommended Action: Contact HP
Support personnel to troubleshoot problem WBEM EventID: 2905. WBEM
ProviderName: FPL_IndicationProviderWarning7893
CC chip fan failed. Probable Cause: The CC chip fan identified by the attached physical
location has failed. Recommended Action: Contact HP Support personnel to
troubleshoot problem WBEM EventID: 2906. WBEM ProviderName:
FPL_IndicationProviderError7894
CC chip fan failing. Probable Cause: The CC chip fan identified by the attached
physical location is not operating at expected speed. Recommended Action: Contact
HP Support personnel to troubleshoot problem WBEM EventID: 2907. WBEM
ProviderName: FPL_IndicationProviderWarning7895
System FW and the PDHC have incompatible shared memory interface revisions.
Probable Cause: (Probable) Either System firmware or PDHC Firmware on the named
cell was upgraded to a new major revision number and not the other. The major
numbers must match when checked by the PDHC or else the cell will not be allowed
to boot. Recommended Action: Use FWUU (Firmware Update Utility) to check the
revision numbers of PDHC and PDC Firmware on the cell(s) called out in the event
log. Compare to other cells in the complex, or, if single cell, check firmware revs.
available to FWUU. WBEM EventID: 4954. WBEM ProviderName:
FPL_IndicationProviderError7896
PDH Controller firmware version is not supported with this version of MP FW.
Probable Cause: PDH Controller firmware version is not supported with this version
of MP FW Recommended Action: Update PDHC or MP firmware WBEM EventID:
707. WBEM ProviderName: FPL_IndicationProviderError7902
Power fault on cell board. Probable Cause: One or more of the DC to DC power
converters on the Cell Power Board is displaying a fault condition. Recommended
Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID:
708. WBEM ProviderName: FPL_IndicationProviderError7903
The CPU Node reported a problem initializing its node in the device tree. Probable
Cause: See additional logs in determine why initialize node failed. There could be a
hardware or PAL problem. WBEM EventID: 2437. WBEM ProviderName:
FPL_IndicationProviderWarning7938
The ExecuteCommand function failed on a CPU. Probable Cause:
Inter-Processor-Interrupts may not be working, or the command may have timed
out. This could be a firmware bug or hardware problem. Look for other clues in the
event log. WBEM EventID: 710. WBEM ProviderName: FPL_IndicationProviderWarning7939
A remote CPU is not prepared to receive a command. Probable Cause: The CPU may
be stuck waiting for a previous command or may not be healthy. This could also be
caused by a system resource contention problem. WBEM EventID: 711. WBEM
ProviderName: FPL_IndicationProviderWarning7940
An error was encountered when executing a PAL_PROC. Probable Cause: PAL was
unable to be successfully called. See other event ids to determine if action needs to
be taken. WBEM EventID: 614. WBEM ProviderName: FPL_IndicationProviderWarning7948
46 WBEM Provider Event Tables