HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
An unknown error has been detected by the PDHC firmware. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:
Recommended Action: Upgrade PDHC firmware to latest revision. If already at
current revision, contact HP support personnel to troubleshoot the problem. WBEM
EventID: 627. WBEM ProviderName: FPL_IndicationProviderWarning8132
An attempt to write to a device on the PDHCs I2C bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 628. WBEM ProviderName: FPL_IndicationProviderWarning8133
An attempt to read from a device on the PDHC's I2C bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 629. WBEM ProviderName: FPL_IndicationProviderWarning8134
An attempt to write to a device on the PDHC's SM bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 630. WBEM ProviderName: FPL_IndicationProviderWarning8135
An attempt to read from a device on the PDHC's SM bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and PDH Daughtercard. WBEM
EventID: 631. WBEM ProviderName: FPL_IndicationProviderWarning8136
Cell boot has been disabled due to a failure setting the frequency registers. Probable
Cause: Invalid data programmed in the Cell's FRU EEPROM or a CPU module's
Scratch/FRU EEPROM. Recommended Action: If in manufacturing, program correct
data in partition specific field of the Cell or CPU Module's FRU EEPROM. Otherwise,
contact HP support personnel to troubleshoot the problem. WBEM EventID: 632.
WBEM ProviderName: FPL_IndicationProviderError8137
An error has occurred while updating System FW. Probable Cause: Other error
indicated by FWUU. Recommended Action: Exit from FWUU, reset the MP using
the XD command, then attempt to update Sytem FW. If repeated attempts to update
the System FW fail, contact HP support personnel to troubleshoot the problem. WBEM
EventID: 633. WBEM ProviderName: FPL_IndicationProviderWarning8138
The PDHC firmware was reset for some unknown reason. Probable Cause: A PDHC
watchdog timer timeout has occurred because the PDHC was stuck in some unknown
state. Recommended Action: Upgrade PDHC firmware to the latest revision. If the
error continues, contact HP support personnel to troubleshoot the PDH Daughtercard
and/or Cell Board. WBEM EventID: 634. WBEM ProviderName:
FPL_IndicationProviderWarning8139
Cell boot has been disabled because setup of a CPU thermal sensor failed. Probable
Cause: A hardware fault exists in the communication path to a CPU module's thermal
sensor, or in the thermal sensor itself. Recommended Action: Contact HP support
personnel to troubleshoot the Cell Board, the PDH Daughtercard, and/or the offending
CPU module. WBEM EventID: 635. WBEM ProviderName: FPL_IndicationProviderError8140
A CPU module has reported overtemp, so will be powered off in 1 minute. Probable
Cause: Excessive heat in the data center has caused the CPU module to heat up
beyond the programmed temperature threshold. Recommended Action: Resolve the
environmental problem, shut down the partition, then PE the Cell off, then on again.
WBEM EventID: 636. WBEM ProviderName: FPL_IndicationProviderError8141
An error occurred while updating the PDHC firmware. Probable Cause: Other error
indicated by Firmware Update. Recommended Action: Exit from Firmware Update,
reset the MP using the XD command, then attempt to update PDHC firmware again.
If repeated attempts to update the PDHC firmware fail, contact HP support personnel
to troubleshoot the problem WBEM EventID: 637. WBEM ProviderName:
FPL_IndicationProviderWarning8143
48 WBEM Provider Event Tables