HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Failed reading an XBC forward progress register. Probable Cause: Fabric access error
Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM
EventID: 726. WBEM ProviderName: FPL_IndicationProviderError8195
Could not find an adjacent XBC due to broken fabric links. Probable Cause: Possible
crossbar failure Recommended Action: Contact HP Support personnel to analyze
the crossbar. WBEM EventID: 727. WBEM ProviderName: FPL_IndicationProviderError8198
The run-time verification of a programming assumption has failed. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:
Upgrade PM firmware to latest revision. If already at current revision, replace UGUY
board. WBEM EventID: 728. WBEM ProviderName: FPL_IndicationProviderWarning8199
An unknown error has been detected by the PDHC firmware. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:
Upgrade PM firmware to latest revision. If already at current revision, replace UGUY
board. WBEM EventID: 729. WBEM ProviderName: FPL_IndicationProviderWarning8200
Data field contains data meant for firmware debug only. Probable Cause: Debug
event. Recommended Action: Contact your hp support representative. WBEM
EventID: 2440. WBEM ProviderName: FPL_IndicationProviderError8202
Testing of correctable errors injected from the CC has failed. Probable Cause: Either
the CC failed to inject the errors, the XBC failed to detect them, or PDC could not
access the XBC CSR. Recommended Action: Check results from other cells connected
to the same XBC. Check CC, Check XBC, Contact HP Support Personnel. WBEM
EventID: 731. WBEM ProviderName: FPL_IndicationProviderWarning8205
A cabinet has been configured using an invalid cabinet number. Probable Cause:
Re-configure cabinet to use a valid cabinet number WBEM EventID: 732. WBEM
ProviderName: FPL_IndicationProviderError8206
Cells trying to join a PD are at incompatible firmware revisions. Probable Cause: The
reporting cell is at a different firmware revision than the cell reported in the data
field. A PD cannot be established. Please reprogram the 2 cells to the same firmware
revision. WBEM EventID: 733. WBEM ProviderName: FPL_IndicationProviderError8207
An attempt to write to a device on the PM's I2C bus has failed. Probable Cause: A
hardware error has occurred. Recommended Action: Replace the UGUY board.
WBEM EventID: 734. WBEM ProviderName: FPL_IndicationProviderWarning8212
An attempt to read from a device on the PM's I2C bus has failed. Probable Cause: A
hardware error has occurred. Recommended Action: Replace the UGUY board.
WBEM EventID: 735. WBEM ProviderName: FPL_IndicationProviderWarning8214
An error was encountered updating the cell info structure in ICM. Probable Cause:
This should not happen. Contact engineering to diagnose the problem. WBEM
EventID: 736. WBEM ProviderName: FPL_IndicationProviderWarning8216
An error was encountered pointing the slave cell consoles to the diva. Probable Cause:
A CPU on the slave cell could not process an interrupt in time or establish the diva
console. WBEM EventID: 737. WBEM ProviderName: FPL_IndicationProviderWarning8218
An error was encountered trying to relocate a slave cells registry. Probable Cause:
There could be a PD rendezvous error or a processor on the slave cell failed to respond
to an interrupt in time. WBEM EventID: 738. WBEM ProviderName:
FPL_IndicationProviderError8219
Complex Profile Group C CRC didn't match the expected value. Probable Cause:
Push out a new Group C complex profile. WBEM EventID: 2441. WBEM
ProviderName: FPL_IndicationProviderError8220
Failure to identify a core cell during Global MCA. Probable Cause: This will lead to
a system reset. WBEM EventID: 1034. WBEM ProviderName: FPL_IndicationProviderError8238
Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred.
Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 742.
WBEM ProviderName: FPL_IndicationProviderWarning8239